3OM-1003-005.pdf - 第260页

(13) Warm-up run (T est Mode) The data of the warm-up run (dry cycle) is counted. P .C.B. counter The number of P .C.B.’s is counted when the machine is oper- ated under the following condition. • "ENABLE" set …

100%1 / 383
(3) Passed P.C.B.
The number of passed P.C.B.’s is counted when the machine is
set in the "PASS" mode.
Counting is implemented when the P.C.B. transfer starts (when
the P.C.B. on the X/Y table is transferred to the output conveyor).
(4) Product P.C.B. (B.B.R.)
Shown is the number of defective P.C.B.'s summed up when
the unit P.C.B. B.B.R. detection function (option) is used
(5) Total components
Shown is the number of picked components (the number of pick-
up operations).
(6) Total handling errors
Shown is the total number of component handling errors.
(7) Rate of handling errors (%)
Shown is the percentage of handling errors per total number of
picked components.
(8) Shortage of component
Shown is the total number of detected component shortage er-
rors.
(9) Waste components
Shown is the total number of components that were picked up
but not placed.
The indicated number of components represents the compo-
nents that were not placed due to a vertical component error
(sensor), a component recognition error, a component thick-
ness error, interrupted production, the detection of unit P.C.B.
(B.B.R.) (option), etc.
(10) Component backtrack
Shown is the total number of component backtrack errors.
(11) Component output error (Pickup error)
Shown is the total number of the output-error-caused compo-
nents (pickup errors).
(12) Component output error (Others)
Shown is the total number of output-error-caused components
(errors other than pickup ones).
4.2 "Machine Performance Data" Tab
051 1-003 4-35 AIL01EDTP
Note
(13) Warm-up run (Test Mode)
The data of the warm-up run (dry cycle) is counted.
P.C.B. counter
The number of P.C.B.’s is counted when the machine is oper-
ated under the following condition.
"ENABLE" set for "TEST RUN" in "Run Mode" Tab Sheet ("OPN.
MODE" Window)
"PCB XFR Err Det Disabled" Check Box Checked
(State in which no P.C.B. is put in and out)
Not Picked Counts
The number of non-picking/non-placement actions is counted
when the machine is operated under the following condition.
"ENABLE" set for "TEST RUN" in "Run Mode" Tab Sheet ("OPN.
MODE" Window)
"Handling/Place Disabled" or "Vacuum/Blower Disabled" Check
Box Checked
(14) P.C.B. process time
Shown is the total of the time required to finish a P.C.B.
4.2 "Machine Performance Data" Tab
0403-001 4-35-1 AIL01EDTP
(15) Power on time
Shown is the period of time during which the control power of
the machine was kept"ON".
Example: 10:03’50"(10 hours, 3 minutes, and 50 seconds)
Auto run time
Shown is the period of time during which the machine was run-
ning automatically.
When a particular pattern program is set several times as cur-
rent one, the sum total is computed.
Placement Time
Shown is the time required to finish a P.C.B. (from the first to the
last component placement on one product P.C.B.).
The essential component placement time is summed up. While
the machine is set in the "STOP" or the "PAUSE" mode or a step
operation is performed, the time is not measured.
This is used to calculate the average placement tact time per
component.
P.C.B. transfer time
Shown is the period of time during which each motor (motors to
drive the L conveyor, the transfer conveyor, the P.C.B. transfer,
and the R conveyor) is being activated.
P.C.B. wait
Input wait
Shown is the period of time during which the machine was
completely in the waiting mode (the machine was waiting for
a P.C.B. to be loaded from the input machine).
Output wait
Shown is the period of time during which the machine was
completely in the waiting mode (the machine was waiting for
a P.C.B. to be unloaded to the output machine).
P.E.C./B.B.R.
Shown is the period of time during which the machine is taking
P.E.C. recognition and B.B.R. detection actions.
Counted is the period of time during which the X/Y table starts
moving and the P.E.C. recognition and B.B.R. detection are com-
pleted
Others
Shown is the period of time during which the machine takes ac-
tions other than the above-described ones.
Included are the periods of time during which the F-axis takes
actions before component placement, the X/Y table returns af-
ter component placement, etc.
4.2 "Machine Performance Data" Tab
0403-002 4-36 AIL01EDTP
Note
Note