3OM-1003-005.pdf - 第329页
051 1-001 5-47-1 AIL01EDTP Mode "Standard", "Bias", or "Sampling Bias" can be selected. Standard Only the normal auto feeder axis adjustment is performed. Bias Compared with "Standard&q…

051 1-002 5-47 AIL01EDTP
*4 Auto feeder axis adjustment set
# of picks [times], (X) adjustment [%], (Y) adjustment [%]
Set the sensitivity parameters which follow up the data learned by
using the statistical method in the feeder (B) offset data.
New "FDR. (B) OFFSET" = Old "FDR. (B) OFFSET" +
(mean of deviation obtained n times) * Coefficient
# of picks [times]
Set the total number of collected samples when data is updated
or changed.
(a) The data input range is "1 to 10".
(b) The standard value is "3".
(X) adjustment [%]
Set the feedback coefficient of the mean of the feeder axis’ X-
direction deviation.
(a) The data input range is "10 to 100%".
(b) The standard value is "50%".
(Y) adjustment [%]
Set the feedback coefficient of the mean of the feeder axis’ Y-
direction deviation.
(a) The data input range is "10 to 100%"
(b) The standard value is "50%"
3.3 "Auto Operation" Tab
Note
Note
Note

051 1-001 5-47-1 AIL01EDTP
Mode
"Standard", "Bias", or "Sampling Bias" can be selected.
Standard
Only the normal auto feeder axis adjustment is performed.
Bias
Compared with "Standard", it is possible to set larger follow-up
sensitivity coefficients of the first and second corrections made
after component replacement.
First Follow-Up
Mean of Deviations (Corrected Values) as Results of n-Time Component Recognitions ×
(((X)
adjustment [%] , (Y) adjustment [%]) + (Bias coefficient (X) [%], Bias coefficient (Y) [%]))
Second Follow-Up
Mean of Deviations (Corrected Values) as Results of n-Time Component Recognitions ×
(((X) adjustment [%] , (Y) adjustment [%]) + (Bias coefficient (X) [%], Bias coefficient (Y) [%])/2)
(a) As for the third and subsequent follow-ups, the de-
viations are the same as those in the standard
specifications.
(b) The result of the 1-time component recognition is
adopted only when "n" is set as "1" (n = 1).
(c) When the coefficients "((X) adjustment [%] , (Y) ad-
justment [%]) + (Bias coefficient (X) [%], Bias coef-
ficient (Y) [%])" or "((X) adjustment [%] , (Y) adjust-
ment [%]) + (Bias coefficient (X) [%], Bias coeffi-
cient (Y) [%])/2" are calculated to be "more than
100%", they are regarded as "100%".
3.3 "Auto Operation" Tab
Note

051 1-001 5-47-2 AIL01EDTP
3.3 "Auto Operation" Tab
Sampling Bias
Compared with "Standard", it is possible to set larger follow-up
and sensitivity coefficients of the first and second corrections
(fixed) made after component replacement.
The follow-ups can be set more sensitive than "Bias".
First Follow-Up
Deviation (Corrected Values) as Result of 1-time Component Recognition ×
(((X) adjustment [%] , (Y) adjustment [%]) + (Bias coefficient (X) [%], Bias coefficient (Y) [%]))
Second Follow-Up
Mean of Deviations (Corrected Value) as Results of 2-time Component Recognitions ×
(((X) adjustment [%] , (Y) adjustment [%]) + (Bias coefficient (X) [%], Bias coefficient (Y) [%])/2)
(a) As for the third and subsequent follow-ups, the de-
viations are the same as those in the standard
specifications.
(b) When the coefficients "((X) adjustment [%] , (Y) ad-
justment [%]) + (Bias coefficient (X) [%], Bias coef-
ficient (Y) [%])" or "((X) adjustment [%] , (Y) adjust-
ment [%]) + (Bias coefficient (X) [%], Bias coeffi-
cient (Y) [%])/2" are calculated to be "more than
100%", they are regarded as "100%".
Bias coefficient (X) [%]
Set the value of the follow-up bias coefficient (X).
Bias coefficient (Y) [%]
Set the value of the follow-up bias coefficient (Y).
Note