错误 ! 使用“开始” 选项卡将 제목 2 应用于要在此处显示的文字。 错误 ! 使用“开始”选项卡将 제목 2 应用 于要在此处显示的 文字。 . 5- 147 [Figure 5- 175 parameter of HSV col or inspectio n win dow] [Figu re 5- 176 Selection example of normal boundary region] 6) Parameter of L…

MV-9 User Manual
5-146
Next, display RGB average value in added color window area.
Refresh display of RGB average value in current color window area.
Extract and display RGB average value (color).
[Figure 5-174 parameter of RGB color inspection window]
5) Parameter of HSV color inspection window
Color coordinator configuration
- convert to HSV using RGB value in the relevant window, and display it in color (H, hue) -
saturation (S, saturation) area (left circle), and display position of luminance (V, value) in
the right bar.
Normal boundary region
- There are 3 methods of 3 points, circle, and pentagon shape to designate normal range of
color in inspection area.
- Designate min – max range to designate normal range of luminance of inspection area
Color reset
- Reset normal color range. Divide color area (0° ~ 360°) in color map into 3 and RGB each
allot, and set saturation to origin.
- Set R, G and B as initial value for each color
Normal range
- Designate inside or outside of normal boundary region as normal range.
- Designate area to which color of inspection window that completed teaching is included
(area displayed in dotted line) for „Inside‟, and designate the other area for „outside‟.

错误!使用“开始”选项卡将 제목 2 应用于要在此处显示的文字。错误!使用“开始”选项卡将 제목 2 应用
于要在此处显示的文字。 .
5-147
[Figure 5-175 parameter of HSV color inspection window]
[Figure 5-176 Selection example of normal boundary region]
6) Parameter of LUV color inspection window
Color coordinator configuration
- Convert to Luv by using RGB value of the relevant window, and display the position of uv
value in coordinate plane, and display the position of luminance value in the right bar.

MV-9 User Manual
5-148
Inspection algorithm and normal range
- Luv
Conduct for inspection for uv value and L.
Normal range can be changed by changing position of polygonal apex on
coordinate plane, and normal range (min-max) of luminance bar can be designated.
- Saturation:
This is to conduct saturation inspection.
Normal range (min-max) can be designated in saturation bar. Coordinate plane and
luminance bar can‟t be modified.
- Total inspection
This is to conduct both of Luv inspection and saturation inspection.
All of coordinate plane, luminance bar and saturation bar can be set.
[Figure 5-177 parameter of LUV color inspection window]
7) Inspection result in status screen
RGB color inspection result
- Inspection color: RGB value of reference model.
- Color and color difference