MV-9_Chapter 5. Teaching.pdf - 第242页
MV -9 Use r Manual 5- 242 5.5.3 Additional functions during inspection window selection This is about popup menu displa yed by c licking right button of the mouse tha t be used w hen inspe c tion window that complete d t…

错误!使用“开始”选项卡将 제목 2 应用于要在此处显示的文字。错误!使用“开始”选项卡将 제목 2 应用
于要在此处显示的文字。 .
5-241
[Figure 5-316 component list]
Component name: component name used for PCB.
Reference name: reference name recorded in PCB
Module: module No.
Library: library name used for teaching
Frame: frame No.
Type: inspection type.
X: X-axis coordinates.
Y: Y-axis coordinates.
Angle: component angle.
Window hid
This is to hide window that completed teaching in frame.
Delete defect information
This is to delete information of defect windows that completed teaching in frame. Only
information will be deleted. defect information will not be judged as normal.

MV-9 User Manual
5-242
5.5.3 Additional functions during inspection window selection
This is about popup menu displayed by clicking right button of the mouse that be used when
inspection window that completed teaching is selected in frame image screen.
[Figure 5-317 inspection window related function]
Inspection
This is used to inspect only the selected inspection window. This is useful to search correct
parameter setting value of the relevant inspection window during teaching. inspection result
will be displayed in the status screen, and many inspection windows can be inspected.
Copy
This is used to create window that has same attribute with selected inspection window.
Cut
This is used to cut selected inspection window.
Paste
This is used to paste inspection window that is already copied or cur in the relevant frame.
Multiple copy
This is used to copy many selected inspection windows at a time.

错误!使用“开始”选项卡将 제목 2 应用于要在此处显示的文字。错误!使用“开始”选项卡将 제목 2 应用
于要在此处显示的文字。 .
5-243
[Figure 5-318 multiple copy]
Special mark
Skip inspection window
This function will immediately skip the selected inspection window. In case of occurrence
of defect in window that is set as skip inspection window, the following PCB will be skipped
without conducting inspection.
Frame compensation mark
If correct substrate compensation can‟t be done by only PCB compensation mark, use
frame compensation mark for more correct inspection.
Angle setting
This is not to rotate teaching window and registered image of the selected inspection window
or component, but newly set only angle window or component that is currently selected.
[Figure 5-319 Angle setting]
To new frame
Not like component that completed teaching in the current frame, use this option to insert
component that newly completed teaching into a new frame.
Grouping components
This is used to group many inspection windows into one component after creating many single
inspection windows.
Component ungroup
This is used to create many single inspection windows for one component and ungroup these
inspection windows into single inspection window.