错误 ! 使用“开始” 选项卡将 제목 2 应用于要在此处显示的文字。 错误 ! 使用“开始”选项卡将 제목 2 应用 于要在此处显示的 文字。 . 5- 251 ⑤ Use Ref Manua l (Setting of Reference Surfac e) - Set m anua lly the region for p l anar i nformation. It is possible to set the height …

MV-9 User Manual
5-250
5.6.4 Selection of Mounting Type
- Select “Chip” in the mounting type.
5.6.5 Position Setting
④ Setting of Expanded Size
- Decide the expanded size for planar information with respect to the floor (PCB or
reference).
- Include the floor surface from all the directions of left, right, top and bottom.
- Mark the expanded area with yellow dotted lines.
Setting of Height Position
- Set the position to calculate the average height of the electrode part at both ends.
- Mark the height position with red dotted lines.

错误!使用“开始”选项卡将 제목 2 应用于要在此处显示的文字。错误!使用“开始”选项卡将 제목 2 应用
于要在此处显示的文字。 .
5-251
⑤ Use Ref Manual (Setting of Reference Surface)
- Set manually the region for planar information.
It is possible to set the height and size together or separately using the check box.
⑥ Detailed Setting
- Set the detailed position for measurement regions of the reference surface and height.
- It is possible to designate the position with a mouse by using „Click Pos‟ button.
5.6.6 Part Information Measurement
Click „Get Info (Measurement)‟ to measure information on the width, depth and height of parts.
* Click „Get Info‟ to display 3D Model, and confirm through the model if the information is normally
measured. (In case it is not measured normally, it is impossible to identify the form of 3D
Model.).
5.6.7 Criteria Setting

MV-9 User Manual
5-252
⑦ On the basis of the currently measured values, the minimum and maximum heights are
determined automatically.
- Minimum Height < Height < Maximum Height
- The minimum height is 1/2 the current one and the maximum height is +100um above
the current height.
- If the measured height is below the minimum height or above the maximum height, the
part is treated as a poor quality one.
⑧ Length Slope
- If the deviation between left and right heights is greater than the length slope, the part is
treated as a poor quality.
- This is used to detect fine lift.
⑨ Rotation Angle (option)
- If the rotational angle of chips is greater than the Rotation Angle, the part is treated as
a poor quality.
⑩ Use Double Chip Insp
- In case of Chip Type, inspect Double Chip.
In case the height is above the designated one, the judgment is based on Double Chip
5.6.8 Inspection Results
⑪ The inspection results are displayed for the items of 3D Chip Mounting for the Type.
- 1 Pos: The average height of the electrode at 1 Pos area.
- 2 Pos: The average height of the electrode at 2 Pos area.
- Length Slope: Display the deviation between left and right heights