NPM-W 2 EJM7DE-MB-03 O-00 Remaining components You can ch eck remaining c omponents per mac hine or line during p roduction. 1 Operating procedure 3-2-1 3-2-1 -5 Produc- tion informa- tion 1 Choose either by machine or b…

NPM-W2 EJM7DE-MB-03O-00
Production
3-2-1-4

NPM-W2 EJM7DE-MB-03O-00
Remaining components
You can check remaining components per machine or line during production.
1
Operating procedure
3-2-1
3-2-1-5
Produc-
tion
informa-
tion
1
Choose either by machine or by line
: By machine
: By line
A
B
TBL (table)
Table to be referred.
Stop production after producing the
current PCB. (→P.3-1-2)
C
How to check the screen in
production, when stationary
3
Status
■When the feeder is out of components
■When the feeder is out of components
but components are in stock
■When the feeder is out of components
and components are also out of stock
■When the tray is out of components
■When the tray is out of components but
components are in stock
■When the tray is out of components and
components are also out of stock
Feeder: White
BG color: Grey
Feeder: White
BG color: Grey, Slash: Yellow
Feeder: White
BG color: Yellow, Slash: Yellow
Tray color: Grey
BG color: Grey
Tray color: Grey
BG color: Grey, Slash: Yellow
Tray color: Grey
BG color: Yellow , Slash: Yellow

NPM-W2 EJM7DE-MB-03O-00
D
Even though component empty
warning is displayed, it is a
misjudgment. So, production is
continued.
E
Illuminates LED of unused feeders.
F
■By machine
H
G
I
ADR (address)
Component address.
CompName
Time
The estimated time to component
empty.
●Unit: minute
J
PCB
The number of PCBs produced before
component empty.
Length
The remaining tape length.
●Unit : m
A B
D
C
HE F
G
J
I
■By line
A B
DC HE F
GA
3-2-1-6
K
K
When the number of components
remaining in a feeder happens to be
incorrect, you can manually enter the
correct number in the Current section.
Production