N7201A616E00_0317.pdf - 第615页

NPM-W 2 EJM7DE-MB-07 O-00 7-3-4 -2 System administration

100%1 / 714
NPM-W2 EJM7DE-MB-07O-00
7-3-4-1
Machine
parame-
ter
Head origin offset
check
You can check the origin offset values (calibration result) of θ-/Z-axes.
A
B
B
A
Operating procedure
7-3-4
θ [°]
Offset angle on head origin.
Z [mm]
Offset of the height direction of Z-axis
of each loading head.
Placement head
A
B
B
A
θ [°]
Offset angle on head origin.
Z [mm]
Offset of the height direction of Z-axis
of each dispensing head.
Dispensing head
NPM-W2 EJM7DE-MB-07O-00
7-3-4-2
System
administration
NPM-W2 EJM7DE-MB-07O-00
You can check rotation center offset (calibration result) of each nozzle head.
B
A
E
C
D
7-3-5-1
Machine
parame-
ter
Head rotation center
check
Operating procedure
7-3-5
Switches the display of [Rotate center]
to the value used in recognizing
components with the multi-recognition
camera.
Rotate center X[mm]/Y[mm]
XY coordinates of rotation center.
Switches to the value being temporarily
retained after measurement.
Standard value of rotation center that is
used in correcting temporal changes.
Amount of change in the reference
rotation center that occurs during
temporal change correction.
Placement head
A B
E DC