N7201A616E00_0317.pdf - 第422页

NPM-W 2 EJM7DE-MB-06O-0 0 6-1-20 -1 You can set the operation conditions or switch a pass table between ON and OFF. A D B Item Shows the previous or next table. Set C Data editing Soft s witc h setting Displays soft swit…

100%1 / 714
NPM-W2 EJM7DE-MB-06O-00
6-1-19-2
F
Check item
Area check:
This shows whether the area inspection
function is enabled or not.
Nozzle total check:
This shows whether the nozzle clogging
inspection function is enabled or not.
Check:
This shows whether the stringiness
inspection function is enabled or not.
Fly pattern check:
This shows whether the skipped pattern
inspection function is enabled or not.
G
Check terms data
Total area low limit (%) :
The lower limit of the total area is
displayed.
Total area up limit (%) :
The upper limit of the total area is
displayed.
Area rate limit (%) :
The limit of the large/small area ratio is
displayed.
Judge value(mm) :
The stringiness judgment value is
displayed.
Ptn min diameter (mm) :
The minimum pattern diameter is
displayed.
The minimum pattern diameter size
should be set to a value lower than the
hole diameter of the nozzle used.
H
Standard area (mm
2
)
Setting
change
NPM-W2 EJM7DE-MB-06O-00
6-1-20-1
You can set the operation conditions or switch a pass table between ON and OFF.
A
D
B
Item
Shows the previous or next table.
Set
C
Data
editing
Soft switch setting
Displays soft switch items.
:Enable.
:Disable.
Operating procedure
6-1-20
A
B
C
D
Set pass
:Pass.
:Not pass.
About settings other than the items
in the next page, see the operating
instruction of NPM-DGS.
NPM-W2 EJM7DE-MB-06O-00
6-1-20-2
Setting
change
6-1-20-2
Setting
change
Item Description
Safe mode action
(For 3-nozzle head)
Perform the following when [ON] is set.
Do not allow superposition of X-axis, Y-axis and Y-axis during
pickup or placement
Do not allow preliminary lowing during pickup or placement.
Pickup check is performed by the vacuum sensor before X-axis or
Y-axis are moved during pickup or placement, and if pickup error is
detected, the action stops regardless of pickup error count.
High production
mode(F)
Perform the following when [ON] is set.
Production is performed in high-production mode on the machine
front side
*1) *2) *3)
High production
mode(R)
Perform the following when [ON] is set.
Production is performed in high-production mode on the machine
rear side.
*1) *2) *3)
*1)
It is enabled when the light weight 16-/12-nozzle head is installed.
*2)
When OFF is set, production is performed in “High-accuracy mode”.
*3)
About “High-production mode” and “High-accuracy mode”. (P.9-1-1 ‘Basic performance’)