N7201A616E00_0317.pdf - 第293页

NPM-W 2 EJM7DE-MB-04O-0 0 4-4-3 -2 Component inspection

100%1 / 714
NPM-W2 EJM7DE-MB-04O-00
1
1
A
NG position on a PCB is displayed on the
map.
B
The inspection result information is
displayed on a per-component basis.
C
Displays the next (second) page.
D
The inspection result information is
displayed on a per-feeder basis.
E
The inspection result information is
displayed on a per-head basis.
Inspection information display
A B C
First page
Second page
D E G
2
F
H
2
Choose a display item
F
The inspection result information is
displayed on a per-nozzle basis.
G
Displays the previous (first) page.
H
Switches the screen to the detailed.
Inspection monitor 1
Operating procedure
4-4-3
Produc-
tion
4-4-3-1
Error information collected in LNB can be checked on screen or via the production information menu on a
production-line or per-machine basis during production. The error information cannot be displayed without
establishing connection to LNB.
2
NPM-W2 EJM7DE-MB-04O-00
4-4-3-2
Component
inspection
NPM-W2 EJM7DE-MB-04O-00
Inspection map
Denominator/Numerator
Denominator: The order of the displayed
inspection NGs.
Numerator: The total number of
inspection NGs.
Comment
Pattern No
Bad item
Displays the number and names of bad
items.
Helps you switch from one item name to
another.
Comp info
The name of the placement component .
Inspection monitor 2
Operating procedure
4-4-3
Produc-
tion
4-4-3-3
1
1
F E
A
BCD
G H
I
KJ
A
B
D
E
F
C
Displays the NG location on a PCB on
the map.
Touching the screen enlarges a
selected defect, with a focus on the
defect.
Check the NG location of the last NG PCB unloaded on the map.
The details of the NG location can be checked by displaying the nature or cause of the defect or enlarging the
display of the NG location map.
Do not press the foot switch of the conveyor before completing the inspection of the NG location or rework.
If the next PCB happened to be unloaded, the map would be updated reflecting the information on the next
PCB.
When an inspection results in NG, a PCB, after being ejected, comes to rest on the ejection conveyor. Also,
the signal tower blinks and a buzzer sounds.
Where inspection results in NG
Where inspection results in OK
Where defect is yet to be inspected
Explanation of the screen