N7201A616E00_0317.pdf - 第533页

NPM-W 2 EJM7DE-MB-06 O-00 6-2-15 -6 Setting change 10 A F A Local H point Measurement points displaying the result measured b y loc al hei ght measurement are displayed. (5 points at maximum) E C B Skip Skip condition fo…

100%1 / 714
NPM-W2 EJM7DE-MB-06O-00
6-2-15-5
Local height teach 3
Produc-
tion data
teaching
Operating procedure
6-2-15
6
: Changes the lamp
:Changes the amount of
adjustment of the lamp value
6
Adjust the lamp value to be
easy to see
7
+
7
98
8
9
(Update the value of [Z] by measuring
the height of local height measurement
coordinates)
Teaching using inching is not available
after height measurement is performed.
Press + to move the
head camera to the local height
measurement coordinate position.
+
(The head camera moves to the next local
height measurement position)
Go though the step from to as
well.
If you perform teaching using inching
operation, data save can be confirmed.
5 7
+
NOTICE
The local height measurement test
result is displayed by performing the
measurement test of the local height
measurement data using the
placement coordinates which are
selected on placement point selection.
NPM-W2 EJM7DE-MB-06O-00
6-2-15-6
Setting
change
10
A
F
A
Local H point
Measurement points displaying the result
measured by local height measurement
are displayed. (5 points at maximum)
E
C
B
Skip
Skip condition for currently displayed
local height measurement points is
displayed. (ON : Skipped)
C
TestPoint/Heigh
The height measured by the coordinates
set using the local height measurement
data is displayed.
D
Check/Height/Difference
The height measured at four points
where they locate 0.2 mm right, left, up
and down directions from measured
coordinates of .
The value of ‘Difference’ indicates the
difference of the value in .
If the difference exceeds 0.030 mm, the
field frame turns in yellow.
E
All/Height
Average, maximum and minimum values
are displayed based on the height
measured result at measurement points (5
points at maximum) using the local height
measurement data which is not specified
as skipped.
F
The displayed local height measurement
point is switched.
B D
10
C
C
NPM-W2 EJM7DE-MB-06O-00
6-2-15-7
Local height teach 4
Produc-
tion data
teaching
Operating procedure
6-2-15
11
To teach the local height measurement
data of another placement points,
choose the placement point for
teaching, move the head camera with
[Camera move] button and go through
the step to to perform again.
If you perform teaching using inching
operation, data save is confirmed.
11
5 10
(Returns to the local height teach screen)
12
The local height teach screen
is exited, transitioning to
another screen