N7201A616E00_0317.pdf - 第347页

NPM-W 2 EJM7DE-MB-05O-0 0 H The displayed inspectio n point is set as misjudgment (confo rming). I The displayed inspectio n point is set as nonconfo rming but placement to the position is carried out. J The displayed in…

100%1 / 714
NPM-W2 EJM7DE-MB-05O-00
Wrong judgment input
screen 1
Operating procedure
5-4-4
The wrong judgment screen is displayed when an inspection result turns out to be defective.
(The following screen will not be displayed and a defective PCB is unloaded as it is if the soft switch (P.5-2-
1) for [Over judge check] is OFF.)
Check visually any inspection-NG location displayed on the screen and set it as either nonconforming or
conforming (misjudgment) before resuming production.
If you want to set solder inspection condition during placement processing after wrong judgment input,
(P.5-5-2)
A
B
E
Comment
F
Pattern No
C
Lane
D
Comp info
Name of placement component (part
name).
NG image display
NG MAP display
(Component inspection /
solder inspection)
Displays the image that
makes a nonconforming
judgment at the moment
Lane No.
Blue frame in the image:
Solder position misalignment
tolerance
Green frame in the image:
Solder data external frame
White frame in the image:
Solder search area
G
CDE F
H JLA
B
NG image
(Component inspection /
solder inspection)
Displays any NG location
on PCB on the map.
NG MAP
IK
G
Produc-
tion
5-4-4-1
1
Over judgment input
Bad item
Displays other defective items.
Denominator/Numerator
Denominator: The order of inspection
NGs.
Numerator: The total number of
inspection NGs.
NPM-W2 EJM7DE-MB-05O-00
H
The displayed inspection point is set as
misjudgment (conforming).
I
The displayed inspection point is set as
nonconforming but placement to the
position is carried out.
J
The displayed inspection point is set as
nonconforming.
K
Displays the screen for NG detail
information.
L
All the undefined inspection-NG points
are collectively set as nonconforming.
The batch setting button cannot be
used unless all inspections are
complete.
5-4-4-2
Solder
inspection
NPM-W2 EJM7DE-MB-05O-00
Wrong judgment input
screen 2
Operating procedure
5-4-4
A
E
B
Comment
C
Pattern No
G
Return to the previous screen.
MeasVal
Displays the measurement value per defect
item.
Fill rate NG: Area rate [%]
Pervasion rate NG: Area rate [%]
Bridge NG: Bridge width [mm]
Misalignment X NG: Misalignment X [mm]
Misalignment amount Y NG: Misalignment
Y [mm]
Shape error NG: Abnormal shape rate [%]
GD
A
D
Bad item
Displays the defect item name regarding
solder displayed on the screen.
B C
E F
Comp info
Name of a placement component (part
name).
F
Threshold
Display the threshold per defect item
Fill rate NG:
Lower limit threshold of area rate NG [%]
Pervasion rate NG:
Upper limit threshold of area rate NG [%]
Bridge NG:
Upper limit threshold of bridge width
NG [mm]
Misalignment amount X NG:
Upper limit threshold of misalignment X
NG [mm] (±)
Misalignment amount Y NG:
Upper limit threshold of misalignment Y
NG [mm] (±)
Shape error NG:
Upper limit threshold of abnormal shape
rate NG [%]
Produc-
tion
5-4-4-3
1
Over judge input
(Displays detailed NG information)