N7201A616E00_0317.pdf - 第285页

NPM-W 2 EJM7DE-MB-04O-0 0 4-3-2 -4 Component inspection

100%1 / 714
NPM-W2 EJM7DE-MB-04O-00
4-3-2-3
Capturing the images of teaching PCB
1
2
+
1 2
3
Confirm the message
4
Confirm the message
3
Capturing the images of
teaching PCB
(PCB after component
placed)
2
Operating procedure
4-3-2
Produc-
tion data
and
teach
Choose the type of a PCB to
load
PCB with components placed by the
machine other than the inspection-head-
installed one
Used to set the PCB color.
PCB with components placed by the
inspection-head-installed machine
Mainly used to set component
inspection parameters.
+
+
4
(Starts capturing the images of an entire
PCB. The images captured will be
stored in the inspection BOX)
The PCB is unloaded after the images
are taken.
A message appears in the absence of
any PCBs in the upstream machine.
NPM-W2 EJM7DE-MB-04O-00
4-3-2-4
Component
inspection
NPM-W2 EJM7DE-MB-04O-00
Checking the lighting condition (Unnecessary under normal condition)
The lighting adjustment function is used only if it is difficult to inspect components under normal lighting
conditions.
Move the inspection head to a component location, and, checking the image, adjust the lighting to the
condition (high contrast condition) best suited for inspection. For your information, if applying the adjusted
lighting condition for the inspection condition, set the lighting condition in 2D inspection editor on a per-
component basis.([NPM-DGS 2D inspection editor])
Operating procedure
4-3-2
1
Name
Comment
Choose the component search
mode.
2
+
1
When the mode is a component name
1
Produc-
tion data
and
teach
Capturing the images of
teaching PCB
(PCB after component
placed)
3
1 2
3
3
Confirm the message
4-3-2-5
(PCB is loaded, and the component
search/image confirmation screen is
displayed)
A message appears in the absence of
any PCBs in the upstream machine.)
+