NPM-W 2 EJM7DE-MB-07 O-00 Machine parame- ter Multi-r ecognition camer a chec k 2 A Light mode ● Transpar ency: Trans parency mode ● 1: Reflection 1 mode ● 2: Reflection 2 mode ● BGA: Reflection BGA mode A B C D 設備に設置されて…

NPM-W2 EJM7DE-MB-07O-00
Checking light luminosity
A
A
Light type Color Description
Transpar-
ency
Red
Transparency lighting
・Luminosity offset value
・Luminosity gain value
Reflection Brown
Reflection lighting
・Luminosity offset value
・Luminosity gain value
●The reflection evaluation
value is used to evaluate
deterioration of light
luminosity
Side Peach
Side lighting
・Luminosity offset value
・Luminosity gain value
B
D
C
D
B
D
C
Enlarged drawing of
E
E
B
C
Light luminosity offset and
luminosity gain value
Side lighting
Transparency lighting
Reflection lighting
7-3-17-2
System
administration

NPM-W2 EJM7DE-MB-07O-00
Machine
parame-
ter
Multi-recognition
camera check 2
A
Light mode
●Transparency: Transparency mode
●1: Reflection 1 mode
●2: Reflection 2 mode
●BGA: Reflection BGA mode
A
B C D
設備に設置されているフィーダーのメモリー情報を表示します。
Multi-recognition camera lamp value
B
Light
C
Standard value
Lamp standard value for each light
mode.
D
Offset
Lamp offset for each light mode.
Display Color Type
Transparency Red
Transparency
lighting
Reflection Brown
Reflection
lighting
Side Peach Side lighting
Enlarged drawing of
H
F EG
EF G
H
E
G
F
Side lighting
Transparency lighting
Reflection lighting
Operating procedure
7-3-17
7-3-17-3

NPM-W2 EJM7DE-MB-07O-00
Machine
parame-
ter
Tray origin offset/
pickup position check
Checking pickup position offset
A
Checking origin offset value
A
B
You can check the tray feeder for the pickup position offset of the tray feeder and the origin offset values of
TP-/TL-axes.
Operating procedure
7-3-18
●TP [mm]
Origin offset of TP-axis of the tray
feeder.
●TL [mm]
Origin offset of TL-axis of the tray
feeder.
Origin offset
Position offset X[mm]Y[mm]
Position offsets of marks A and B in X-
/Y-directions.
Position offset Z[mm]
Position offsets of mark C, D and E in Z-
direction.
7-3-18
System
administration
A B
B
Switches between Tray
A/ B.
■For the twin tray feeder
■For a single tray feeder,
not displayed.
A
B
C
C
Switches between Trays
A /B.
■For the twin tray feeder
■For the single tray feeder,
not displayed.