N7201A616E00_0317.pdf - 第531页
NPM-W 2 EJM7DE-MB-06O-0 0 6-2-15 -4 Setting change 4 + ● The PCB is checked and the rail width is adjusted as necessary. 4 A F A CompName The co mponent name to place to the Placement c oordinates mea suring the local he…

NPM-W2 EJM7DE-MB-06O-00
6-2-15-3
Local height teach 2
Produc-
tion data
teaching
Operating procedure
6-2-15
1
1
In this section, typical local height teach procedure is explained.
This explanation is under the condition that the dispensing head and the height sensor are attached to the
front side head.
●You can operate only when the table with the height sensor placed is selected.
3
3
2
2
Choose the desired data to
perform local height teach

NPM-W2 EJM7DE-MB-06O-00
6-2-15-4
Setting
change
4
+
●The PCB is checked and the rail width
is adjusted as necessary.
4
A
F
A
CompName
The component name to place to the
Placement coordinates measuring the
local height by teaching.
5
Teach local height coordinates
E D C
B
5
B
Measurement point
The points of local height measurement
data target for teach are displayed. (5 points
at maximum)
C
Z
The misaligned amount from the PCB
top surface reference at selecting local
height measurement coordinates.
D
X/Y
The amount of inching for position
adjustment
E
The view size of the recognition image is
changed.
F
The amount of inching for position
adjustment is changed.
●After changing to the PCB loading standby
status, place the PCB on the loading entrance.
(Unnecessary if the PCB has already been on
the stage)
NOTICE
●
+

NPM-W2 EJM7DE-MB-06O-00
6-2-15-5
Local height teach 3
Produc-
tion data
teaching
Operating procedure
6-2-15
6
● : Changes the lamp
:Changes the amount of
adjustment of the lamp value
6
Adjust the lamp value to be
easy to see
7
+
7
98
8
9
(Update the value of [Z] by measuring
the height of local height measurement
coordinates)
●Teaching using inching is not available
after height measurement is performed.
Press + to move the
head camera to the local height
measurement coordinate position.
+
(The head camera moves to the next local
height measurement position)
●Go though the step from to as
well.
●If you perform teaching using inching
operation, data save can be confirmed.
5 7
+
NOTICE
●The local height measurement test
result is displayed by performing the
measurement test of the local height
measurement data using the
placement coordinates which are
selected on placement point selection.