N7201A616E00_0317.pdf - 第531页

NPM-W 2 EJM7DE-MB-06O-0 0 6-2-15 -4 Setting change 4 + ● The PCB is checked and the rail width is adjusted as necessary. 4 A F A CompName The co mponent name to place to the Placement c oordinates mea suring the local he…

100%1 / 714
NPM-W2 EJM7DE-MB-06O-00
6-2-15-3
Local height teach 2
Produc-
tion data
teaching
Operating procedure
6-2-15
1
1
In this section, typical local height teach procedure is explained.
This explanation is under the condition that the dispensing head and the height sensor are attached to the
front side head.
You can operate only when the table with the height sensor placed is selected.
3
3
2
2
Choose the desired data to
perform local height teach
NPM-W2 EJM7DE-MB-06O-00
6-2-15-4
Setting
change
4
+
The PCB is checked and the rail width
is adjusted as necessary.
4
A
F
A
CompName
The component name to place to the
Placement coordinates measuring the
local height by teaching.
5
Teach local height coordinates
E D C
B
5
B
Measurement point
The points of local height measurement
data target for teach are displayed. (5 points
at maximum)
C
Z
The misaligned amount from the PCB
top surface reference at selecting local
height measurement coordinates.
D
X/Y
The amount of inching for position
adjustment
E
The view size of the recognition image is
changed.
F
The amount of inching for position
adjustment is changed.
After changing to the PCB loading standby
status, place the PCB on the loading entrance.
(Unnecessary if the PCB has already been on
the stage)
NOTICE
+
NPM-W2 EJM7DE-MB-06O-00
6-2-15-5
Local height teach 3
Produc-
tion data
teaching
Operating procedure
6-2-15
6
: Changes the lamp
:Changes the amount of
adjustment of the lamp value
6
Adjust the lamp value to be
easy to see
7
+
7
98
8
9
(Update the value of [Z] by measuring
the height of local height measurement
coordinates)
Teaching using inching is not available
after height measurement is performed.
Press + to move the
head camera to the local height
measurement coordinate position.
+
(The head camera moves to the next local
height measurement position)
Go though the step from to as
well.
If you perform teaching using inching
operation, data save can be confirmed.
5 7
+
NOTICE
The local height measurement test
result is displayed by performing the
measurement test of the local height
measurement data using the
placement coordinates which are
selected on placement point selection.