N7201A616E00_0317.pdf - 第610页

NPM-W 2 EJM7DE-MB-07 O-00 7-3-1 Machine parame- ter XY position of fset /XY r efer ence mar k c heck A B 設備に設置されている フィーダー の メモリー 情報 を 表示します 。 XY origin offset You can check the origin offset val ues (calibration result) …

100%1 / 714
NPM-W2 EJM7DE-MB-07O-00
7-2-14-2
F
Button Action
A
Moves a pallet to the
supply position.
Moves a pallet to the
pickup position.
Stores a pallet to the
magazine.
Draws out a pallet from
the magazine.
Replaces a magazine.
Unlocks a magazine cover.
Opens the supply shutter.
Closes the supply shutter.
Opens the magazine
shutter.
Closes the magazine
shutter.
Turns ON the lamp.
Turns OFF the lamp.
+
+
To change a pallet moving speed
Choose a pallet moving
speed.
To perform other actions
How to view the table below (*when opening the supply shutter)
(the supply shutter)
System
administration
NPM-W2 EJM7DE-MB-07O-00
7-3-1
Machine
parame-
ter
XY position offset /XY
reference mark check
A
B
設備に設置されているフィーダーメモリー情報表示します
XY origin offset
You can check the origin offset values (calibration result) of X-/Y-axes.
XY standard mark
You can check the offset value (calibration result) to move the head to the XY standard mark position.
B
A
A
A
Operating procedure
7-3-1
Origin offset X[mm]/Y[mm]
The criterion for X-/Y-axes actions and
the origin offset value of each axis.
Install X[mm]/Y[mm]/Z[mm]
The criterion for X-/Y-axes actions that
is used in installing the head, and the
origin offset value of each axis.
Standard mark coordinates
X[mm]/Y[mm]
XY coordinate offset of the standard
mark of the transfer conveyor.
For dual conveyor
(Select a lane in advance)
NPM-W2 EJM7DE-MB-07O-00
7-3-2
Machine
parame-
ter
Placement position
offset check
Operating procedure
7-3-2
You can check placement position offset.
Multi-recognition camera
X[mm]/Y[mm]/ θ[°]
Displays X-, Y- and θ-coordinates
corresponding to the multi-recognition
camera on the placement position offset.
A
B
B
A
Z [mm]
Displays Z-coordinate on the
placement position offset.
Placement head
A
B
B
A
Dispensing head
Dispensing
X[mm]/Y[mm]/ θ[°]
Displays X-, Y- and θ-coordinates
corresponding to the placement position
offset (dispensing).
Z [mm]
Displays the Z-coordinate on the
placement position offset (dispensing).
System
administration