NPM-W 2 EJM7DE-MB-06O-0 0 6-1-21 -2 L Pickup keep The time to lower the transfer head while a component is picked u p. ● Unit: ms. Whether a pickup learning function is enable d or not. Pickup Learn O Mount Check P Nozzl…

NPM-W2 EJM7DE-MB-06O-00
Data
editing
Library check 1
Describes how to check available nozzles or feeder information.
●Edit on NPM-DGS if necessary.
Nozzle library (placement head)
6-1-21-1
Operating procedure
6-1-21
A
B
H
Max Height
F
G
Pickup height
Size X/Size Y
C
E
Nozzle information
(→P.6-1-21-1, -2)
NozzleName
Nozzle total height.
●Unit: mm.
The height from the nozzle top to the
pickup surface.
●Unit: mm.
The dimension in the X-/Y-direction as
seen from the top of the nozzle.
●Unit: mm.
C A
B
Shows the previous or next table.
(Scrolls the table to the right.)
D
NzlNo.
I
Recog Mode
Nozzle recognition method.
Recognition
mode
Nozzle recognition
method
Reflect Reflection recognition
Transparency Transparency recognition
Both
Available for both
reflection and
transparency recognition

NPM-W2 EJM7DE-MB-06O-00
6-1-21-2
L
Pickup keep
The time to lower the transfer head
while a component is picked up.
●Unit: ms.
Whether a pickup learning
function is enabled or not.
Pickup Learn
O
Mount Check
P
Nozzle Check
Q
Whether a placement check by a flow
sensor is enabled or not.
Nozzle existence.
J
K
L
M
N
O
P
J
Vacuum Break
The time interval from when the nozzle
has reached the placement bottom
dead point after switching the vacuum
break blow, while a component is
placed.
●Unit: ms.
Vacuum Stand
The time interval from when the nozzle
has reached the pickup bottom dead
point after switching the vacuum valve,
while a component is picked up.
●Unit: ms.
■The table of nozzle information
C
Fixed column
Horizontal scrolling with or
A
Q
D F H
E G I
M
Mount Keep
The time to lower the transfer head
while a component is placed.
●Unit: ms.
Studded Detect
N
Judgment value of nozzle clogging
detection.
K
Adhesion check
R
There is nozzle adhension check or not.
R
Setting
change

NPM-W2 EJM7DE-MB-06O-00
Data
editing
Library check 2
6-1-21-3
B
Type
PickupCalX/Y
C
Set Pitch
D
FeedVol
E
Tape Width
F
Feeder library
B
C
D
E
F
A
A
Shows the previous or next table.
Offset of a feeder pickup position.
The number of slots occupied by a feeder.
Operating procedure
6-1-21