N7201A616E00_0317.pdf - 第711页

NPM-W 2 EJM7DE-MB-09O -00 Specifi- cation Operating procedure 9-1-12 Suppor ting placement accur acy ± 0.025 mm (Option) At a glance Item Description Head Light weight 16-nozzle head Production mode High production mode …

100%1 / 714
NPM-W2 EJM7DE-MB-09O-00
9-1-11
Specifi-
cation
Operating procedure
9-1-11
Supporting 03015R
component placement
(Option)
Item Description
Head Light weight 16-nozzle head
Nozzle
No.276S No.276SN
Feeder 4 mm double tape feeder (custom specifications)
*1)
Production mode High production mode “OFF”
*2)
Component 03015R (Panasonic)
*3)
Placement angle
The following four angles only: 0/90/180/270°
*2)
Component recognition Placement angle recognition
*2)
Others
The inspection head of the NPM series and the APC function
are not supported
NPM-W2 supports 03015 chips under the following specifications.
*1) For 4 mm feeder, contact PSFC, or sales subsidiary / sales agency.
*2) How to set (See P.6-1-20 ‘Soft switch setting’)
*3) Parts except for 03015R (Panasonic) are excluded from warranty.
NPM-W2 EJM7DE-MB-09O-00
Specifi-
cation
Operating procedure
9-1-12
Supporting placement
accuracy ±0.025 mm
(Option)
At
a glance
Item Description
Head Light weight 16-nozzle head
Production mode High production mode “OFF”
*1)
Component 1005JIG
*2)
Placement angle
The following four angles only; 0/90/180/270°
Component recognition Placement angle recognition
*1)
Placement accuracy
±0.025 mm (Cpk 1)
NPM-W2 supports an accuracy of ±0.025 mm under the following specifications.
*1) How to set (See P.6-1-20 ‘Soft switch setting’)
*2) Above placement accuracy are guaranteed under the use of 1005JIG chip
9-1-12-1
NPM-W2 EJM7DE-MB-09O-00
9-1-13
Specifi-
cation
Operating procedure
9-1-13
NOTICE
Independent
changeover support
unit
(option)
Attaching the independent changeover support unit (movable cover) enables you to change the feeder cart
while changeover is performed in independent mode. However, the machines which have the following
specifications do not support such function.
A machine whose transport conveyor is single lane specifications
A machine whose part supply is tray specifications or 13 series supply unit specifications (attachable
only on the front side)
A stage with the safety cover installed (No dispensing head, inspection head or head)
However, a machine with the dispensing head and feeder cart (30 series) specifications, is attachable
Install only on the rear stage
Independent changeover
support unit
Example of use
Independent mode
Independent mode + alternative (front / rear) mode
Independent mode
alternative (front / rear) mode
The feeder cart can be changed
while changeover is performed in
independent mode
The feeder cart can be changed
while changeover is performed in
independent mode
Do not place anything on the movable cover. Otherwise it can cause troubles.