NPM-W 2 EJM7DE-MB-06O-0 0 6-2-15 -5 Local height teac h 3 Produc- tion data teaching Operating procedure 6-2-15 6 ● : Changes the lamp :Changes the amou nt of adjustment of the lamp value 6 Adjust the lamp value to be ea…

NPM-W2 EJM7DE-MB-06O-00
6-2-15-4
Setting
change
4
+
●The PCB is checked and the rail width
is adjusted as necessary.
4
A
F
A
CompName
The component name to place to the
Placement coordinates measuring the
local height by teaching.
5
Teach local height coordinates
E D C
B
5
B
Measurement point
The points of local height measurement
data target for teach are displayed. (5 points
at maximum)
C
Z
The misaligned amount from the PCB
top surface reference at selecting local
height measurement coordinates.
D
X/Y
The amount of inching for position
adjustment
E
The view size of the recognition image is
changed.
F
The amount of inching for position
adjustment is changed.
●After changing to the PCB loading standby
status, place the PCB on the loading entrance.
(Unnecessary if the PCB has already been on
the stage)
NOTICE
●
+

NPM-W2 EJM7DE-MB-06O-00
6-2-15-5
Local height teach 3
Produc-
tion data
teaching
Operating procedure
6-2-15
6
● : Changes the lamp
:Changes the amount of
adjustment of the lamp value
6
Adjust the lamp value to be
easy to see
7
+
7
98
8
9
(Update the value of [Z] by measuring
the height of local height measurement
coordinates)
●Teaching using inching is not available
after height measurement is performed.
Press + to move the
head camera to the local height
measurement coordinate position.
+
(The head camera moves to the next local
height measurement position)
●Go though the step from to as
well.
●If you perform teaching using inching
operation, data save can be confirmed.
5 7
+
NOTICE
●The local height measurement test
result is displayed by performing the
measurement test of the local height
measurement data using the
placement coordinates which are
selected on placement point selection.

NPM-W2 EJM7DE-MB-06O-00
6-2-15-6
Setting
change
10
A
F
A
Local H point
Measurement points displaying the result
measured by local height measurement
are displayed. (5 points at maximum)
E
C
B
Skip
Skip condition for currently displayed
local height measurement points is
displayed. (ON : Skipped)
C
TestPoint/Heigh
The height measured by the coordinates
set using the local height measurement
data is displayed.
D
Check/Height/Difference
The height measured at four points
where they locate 0.2 mm right, left, up
and down directions from measured
coordinates of .
The value of ‘Difference’ indicates the
difference of the value in .
If the difference exceeds 0.030 mm, the
field frame turns in yellow.
E
All/Height
Average, maximum and minimum values
are displayed based on the height
measured result at measurement points (5
points at maximum) using the local height
measurement data which is not specified
as skipped.
F
The displayed local height measurement
point is switched.
B D
10
C