SIPLACE Feeder Ma nager 3.3 (R18 -1) / Getting S tarted 08/2018 Edition 135 Figure 14 - 20 : X Feeder ID Associ ation – Feeder( s) updated  Tap on M enu  Close to ex it the screen. Or Menu  Clear Form to perform the f…

100%1 / 152
SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
134
Figure 14-18: Save confirmation after track ID scan
Tap Yes to save the association result immediately.
Or No to go to the summary page. The following screen is displayed, in which the track just
scanned is indicated.
Figure 14-19: X Feeder ID Association with Track
Tap on Save to save the entries.
Or tap Menu Close to cancel the association.
If Save is selected, the following screen is displayed indicating the association is successful.
SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
135
Figure 14-20: X Feeder ID Association – Feeder(s) updated
Tap on Menu Close to exit the screen.
Or Menu Clear Form to perform the function for another feeder.
14.3.3 Change Feeder Type
With this function the user can define a feeder type for an unknown feeder type.
When the system detects a new feeder ID for customer specific feeder IDs and the ID
matches the defined customer specific format, the system will automatically register the
feeder ID by setting the feeder type to Unknown. The user can then change the feeder type by
selecting an existing feeder type from the drop-down list.
Select Change Feeder Type in the Main menu.
The following screen is displayed.
Figure 14-21: Change Feeder Type – Select Feeder Type
Select Feeder Type tab
Select a feeder type from the list.
The system will prompt the user to scan a feeder.
SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
136
Figure 14-22: Change Feeder Type – Feeders
Feeders tab
Scan the feeder barcode of the feeder. (Scan all possible feeders to change the feeder
type)
Tap on Save to save the feeder type.
Tap on Close to exit the screen.
14.3.4 Mark Feeder as Defective
With this function the user can mark a feeder as defective and enter a defect comment.
Select Mark Feeder as Defective in the Main menu.
The following screen is displayed.
Figure 14-23: Mark Feeder as Defective
Scan the feeder barcode of the feeder that shall be marked as defective.