00198178-04_GS_FeederManager_3.3_R18-1_EN.pdf - 第78页
SIPLACE Feeder Ma nager 3.3 (R18 -1) / Getting S tarted 08/2018 Edition 78 9.1 Common Co nfiguration W hen the Setting dialog is opened, the first tab Co mmon Conf iguration is s elected by default. Figure 9-3 Setting s …

SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
77
9 Settings menu
Click on Settings button in the menu bar to open the Setting dialog.
Figure 9-1 Settings menu button
From the Settings function, the user can
1) Define a common configuration,
2) Make global settings,
3) Define feeder and location ID format,
4) Define barcode label printing format for feeders and locations,
5) Change user passwords
Note:
The language change function which was previously parked under Settings, is now
accessed from the ASM Studio main menu.
Figure 9-2 ASM Studio Language Change

SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
78
9.1 Common Configuration
When the Setting dialog is opened, the first tab Common Configuration is selected by
default.
Figure 9-3 Settings - Common Configuration
Inside the Common Configuration, following connections can be configured.
1) FM Server connection
2) OIB Core connection
3) X-Feeder Test connection (X-FVS)
4) XFTS connection
5) SFTS connection
9.1.1 FM Server and OIB Server Connection
Feeder Manager Server and OIB Core Server connection can be configured by the following
fields.
Figure 9-4 FM Server and OIB Server configuration

SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
79
Server:
Host name or IP address for the two servers will be filled based on the ones provided by the
user during installation.
The user can modify these entries as needed.
Connection status
The connection status (Connected or Disconnected) is displayed for the servers of the
configuration.
Test Connection button can be used to verify the correctness of the entered server host
name or IP address. Once pressed, the connectivity will be checked, and a pop up dialog will
inform the user whether the test is successful or not.
Note: After test connection, the user need to explicitly save it, otherwise the change will not
take effect.
9.1.2 X-Feeder Test connection (X-FVS)
For the Feeder Manager integration the following options are provided in the Common
Configuration tab.
Figure 9-5 Settings view – X Feeder Test
None
The option is enabled by default after a new installation.
Enable X-Feeder Test Station (X-FVS)
Enable the option for X-FVS integration. After pressing the Save button, the Feeder Manager
will start to monitor the directory specified in the Transfer Directory. The Feeder Manager
Client checks if the option Export test result to feeder manager under Extras – Feeder
Manager Adjustment is enabled. If not the following warning is displayed:
Figure 9-6 Warning message
Note:
After changing settings in X-FVS software, the software must be closed for the
changes to make effective. Otherwise, the changes are not received by the
Feeder Manager.