SIPLACE Feeder Ma nager 3.3 (R18 -1) / Getting S tarted 08/2018 Edition 21 5 Feeder centric functions Feeder Manager Cl ient provides follo wing feeder centr ic functions 1) Add New Feeder 2) Add New Feeders by Batch 3) …

100%1 / 152
SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
20
4.3.9 Application-orientated operation by using color marks
On the Feeder Manager Client, the feeders are marked with feeder colors in order to monitor
the status of the feeder (i.e. maintenance status is defective/due/normal/overdue).
In FM Client, FM Line Console and on the PDA device the following color marks are used:
Color
Feeder
Status
Maintenanc
e Status
Meaning
Red
Blocked
Defective
The feeder is defective.
Red
Blocked
Overdue
The feeder is overdue for maintenance or
the cycle count for this feeder is overdue.
Red
Available/
In Use
Overdue
The feeder is overdue for maintenance or
the cycle count for this feeder is overdue.
Orange
Available/
In Use
Due
The feeder is due for maintenance or the
cycle count for this feeder is due.
Green
Available/
In Use
Normal
The feeder is available or in use.
Table 4-2: Feeder Manager coloring scheme
SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
21
5 Feeder centric functions
Feeder Manager Client provides following feeder centric functions
1) Add New Feeder
2) Add New Feeders by Batch
3) Search Feeder
4) Assign Feeders to Location
5) Feeder Maintenance Workflow
6) Feeder Repair Workflow
5.1 Add New Feeder & Feeder Details view
Add New Feeder function is used to add new X or S feeders in a manual process. It can be
accessed from the Menu bar by clicking on Add Add New Feeder or from Feeder Add
New Feeder.
Following is the Add New Feeder tab opened in the view area.
Figure 5-1: Add New Feeder view
Enter the details for the feeder and save them to add a new feeder to the system.
5.1.1 Add New Feeder view and Feeder Console tab
Following fields are displayed in the Add New Feeder view.
Feeder ID
By default the feeder ID is indicated as SYSTEM ASSIGNED, which means the Feeder
Manager system will assign the feeder ID automatically when you confirm the feeder
registration by clicking the Save button.
However, if you want to enter a feeder ID of your own choice, find the Feeder ID Format
setting in the global setting, and change the selection to External Feeder ID. See chapter 9
section 9.1.5 for details.
SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
22
Feeder serial number
Allows the user to enter the serial number of the feeder.
Note:
By scanning the vendor label, the feeder ID and the serial number will be registered
for the feeder.
Feeder type
Allows the user to select the feeder type to which the feeder belongs.
Note:
If you select “Add New X Feeder”, following dialog will pop up and guide you through
the rest of the feeder registration process
Figure 5-2 Add New X Feeder dialog
To avoid any typing errors, the X feeder information can only be entered by scanning
the feeder barcode. Manual entering is not accepted.
Feeder provider
Allows the user to enter the name of the feeder provider.
At this point of time, the Feeder Status will be shown as Available, and the Feeder
Maintenance Status will be Normal. Both of these two fields are not editable.
Warranty Start Date & Expiry Date
Allows the user to enter the starting date and expiry date of feeder warranty information.
Feeder location
Allows the user to select the feeder location from the drop-down list. The value Unknown
Location is the default.
Note:
Once a feeder is assigned to a known location, it cannot be assigned to Unknown
Location again.
Feeder description
Allows the user to enter a free-text description of the feeder.