SIPLACE Feeder Ma nager 3.3 (R18 -1) / Getting S tarted 08/2018 Edition 88 9.2 General Settings  Click on Setting s – General S ettings tab to open the vie w. Figure 9- 21 : General Settings tab 9.2.1 Description of the…

100%1 / 152
SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
87
- <Position>Left</Position>
- <Result>Pass</Result>
- <Cycle>164240</Cycle>
- </Division>
- <Division>
- <Position>Right</Position>
- <Result>Pass</Result>
- <Cycle>201612</Cycle>
- </Division>
</Feeder>
In order for this test result to be imported by Feeder Manager into the maintenance history of
the correct feeder, the target feeder's serial number must be " KL-B7-0025" (without the part
up to _)
Figure 9-20 SFTS Test Result - Matching Feeder Serial Number
9.1.5 Description of the buttons
Save
Click on this button to save the changed configuration.
Restore to default
Click on this button to restore all the configurations to default value.
SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
88
9.2 General Settings
Click on Settings – General Settings tab to open the view.
Figure 9-21: General Settings tab
9.2.1 Description of the fields
Scanner Timeout
Allows the user to modify the timeout in milliseconds (ms) for the scanner. If no input is
captured in the timeout period, the screen is reset. Default value is 300000 ms (5 minutes).
Display Service screen pop up interval
Allows the user to modify the time interval in minutes (min) for the SIPLACE Display Service
window to reappear on the station computer screen after last dismissal by the operator.
Feeder Location History Setting
Allows the user to set the maximum time for the feeder location assignment history to be
maintained by Feeder Manager. Assignment history records which are older than the time set
here will be deleted automatically. Default value is 3 months.
Feeder Default Location Setting
Allows the user to set the default location when adding new S feeders manually. Default value
is “Unknown location”.
SIPLACE Feeder Manager 3.3 (R18-1) / Getting Started 08/2018 Edition
89
Feeder Maintenance Extension Times
Allows the user to set the maximum times a feeder’s due date or cycle count can be
extended. Minimum value is 1 while maximum is 3 times.
Enforced Feeder Block Options
Allows the user to enable / disable the enforced feeder blocking function.
If this option is enabled, when Setup Center or station software enquires about a certain
feeder’s status, Feeder Manager will return the status as either Normal, Defective, Due,
Overdue or Scrapped. If the feeder is not in Normal status, the online / offline verification will
fail.
If this option is disabled (unchecked), the feeder status will not affect the setup verification or
production.
The user can enable this option for either Online, Offline, or both.
Please take note that for this function to work, the user must enable the “Feeder External
Control” option inside Setup Center’s Settings page. See below.
Figure 9-22 Setup Center's Feeder External Control settings