00196625-03_AI_SX12_PCB_Barcode_de_en.pdf - 第111页
Introduction Manufacturer/Supplier Liability Other Instructions PCB Barcode LP-Barcode 111 1.3.4.3 Handling ESD Modules Do not touch ele ctronic mo dules unles s it is absolute ly essent i al to do so in order to carry o…

Introduction
Other Instructions Contents of This Manual
110 PCB Barcode LP-Barcode
1.3 Other Instructions
1.3.1 Contents of This Manual
This manual contains basic notes on assembly, operation and maintenance of the module. The service
engineers, qualified staff, operators and users must therefore read it before commencing installation and
commissioning.
1.3.2 Environmentally-Friendly Disposal of Materials and Components
SIPLACE products are manufactured using only materials and parts that can be easily separated and
disposed of in an environmentally-friendly way. Hazardous materials are not necessary for the installa-
tion, dismantling or operation of the machine.
1.3.3 Use of Original SIPLACE Accessories and Spare Parts
Only use original spare parts and authorized accessories. The use of other parts will affect safety and
will invalidate the liability for any consequential damage.
1.3.4 ESD Guidelines
1.3.4.1 Definition of ESD
1.3.4.2 Important Measures to Protect Against Static Charging
► Most plastics can easily become charged and must therefore be kept away from at-risk components.
► Always ensure that people, the workplace and packaging are safely earthed when handling electro-
static sensitive components.
NOTICE
Observe the applicable regulations
The company operating the system has sole responsibility for the proper, environmentally-
friendly disposal of machines, working materials, consumables and wear parts.
► Please observe your national statutory provisions for waste disposal and environmental
protection.
Almost all of the modules in use today are equipped with highly integrated MOS blocks and compo-
nents. The manufacturing techniques used mean that these electronic components are extremely sen-
sitive to overvoltage and thus to electrostatic discharge.
The abbreviation for such modules is 'ESD' (Electrostatic Sensitive Device). This is
used internationally, although the German abbreviation 'EGB' may also be seen. The
following symbol on cabinet rating plates, racks or packaging indicates that compo-
nents which are sensitive to electrostatic discharge have been used and thus that the
modules concerned are also touch-sensitive.
ESDs can be destroyed by voltages and power levels that are far below the level that can be perceived
by humans. Such voltages occur if a person touches a component or module without earthing them-
selves. Components that are exposed to such overvoltages do not generally appear to be defective im-
mediately - incorrect behavior starts after the component or module has been in operation for some
time.

Introduction
Manufacturer/Supplier Liability Other Instructions
PCB Barcode LP-Barcode 111
1.3.4.3 Handling ESD Modules
Do not touch electronic modules unless it is absolutely essential to do so in order to carry out other work.
If it is necessary, make sure that you do not touch the pins or printed conductors when you pick up flat
modules.
Do not touch components unless
▪ You are constantly earthed by an ESD wrist strap or
▪ You are wearing ESD shoes or ESD shoe earthing strips on an ESD floor.
Always discharge yourself before you touch an electronic module. To do this, simply touch a conductive
and earthed object immediately before you touch the module (such as unpainted parts of a switch cab-
inet, a water pipe, etc.).
Do not allow modules with chargeable and highly insulating materials to touch one another, e.g. plastic
films, insulating table surfaces or items of clothing made from synthetic fibers.
Always place the modules on a conductive surface (table with an ESD coating, conductive ESD foam,
ESD bag or container).
Do not bring modules near visual display units, monitors or televisions. Keep them at least 10 cm away
from the screen.
1.3.4.4 Measurements and Modifications to ESD Modules
Measurements of the assemblies may only be taken if
▪ The measuring device has been grounded (e.g. via protective conductor) or
▪ The measuring head of the potential-free measuring device has been briefly discharged before
measurement (e.g. touching blank metal control unit housing).
► Always use an earthed soldering iron if you carry out any soldering work.
1.3.4.5 Dispatching ESD Modules
► Always store modules and components in conductive packaging (e.g. metallized plastic bags or met-
al sleeves) and dispatch them in conductive packaging.
► If the packaging is not conductive, place the modules in a conductive envelope before packaging.
Use conductive foam rubber, ESD bags, domestic aluminum foil or paper, for example. NEVER use
plastic bags or film.
► If the module has integral batteries, ensure that the conductive packaging does not touch or short-
circuit the battery terminals and, if necessary, first cover the terminals with insulating tape or mate-
rial.
1.3.5 Manufacturer/Supplier Liability
We draw your attention to the fact that these instructions only contain descriptive and explanatory ma-
terial and do not include any contractual conditions or undertakings. All obligations of ASM proceed from
the conclusion of the contract concerned, under which you have the machine described herein. This ap-
plies in particular to all statements regarding performance or service life and the agreed liability for faults
or defects. The provisions of the contract regarding the liability for faults or defect are neither extended
nor restricted by any statements in this manual.
1.3.6 Release History
Release Changes
03/2011 First edition
12/2011 Revision
04/2012 With addition of conveyor SX V2
Introduction
Other Instructions Correct Usage
112 PCB Barcode LP-Barcode
1.3.7 Correct Usage
The product may only be used for the application described in the catalogues and technical specifica-
tions i.e. for placement of SMD components and only in connection with the third party devices and com-
ponents recommended or approved by ASM.
Any other use is deemed to be incorrect and not as prescribed.
If the product is not used as prescribed, ASM accepts no liability for any damage that may occur and
does not guarantee that the components will work properly and without problems.
Prescribed or correct usage includes the observance of all the instructions in the user manual.
The proper and safe operation of the product requires correct transportation, storage, installation and
assembly, plus careful, accurate utilization and servicing.
1.3.8 Incorrect Usage
Failure to use the product as prescribed can result in both danger to life and limb and material damage.
For this reason any use that is not prescribed is not allowed. If the product is not used as prescribed,
ASM accepts no liability for any damage that may occur and does not guarantee that the components
will work properly and without problems.
Failure to use the product as prescribed includes, for example:
▪ The use on other machines than those machine types officially approved by ASM for this product.
▪ The use of the product in a working environment which deviates from that described in this manual.
▪ Use of the placement machine with the installed product by unqualified personnel.
1.3.9 Electromagnetic Compatibility (EMC)
All SIPLACE products are designed and tested for professional use in industrial applications. Electro-
magnetic compatibility in terms of the emission of interference cannot be guaranteed in any other envi-
ronment.
1.3.10 SIPLACE on the World Wide Web (WWW)
Log into our SIPLACE
®
homepage at http://www.siplace.com.
► You can choose between the German and English versions.
The different sections contain information about our products, services and contact persons.
In addition, registered customers can access the
SIPLACE User Group
. Here you can call up special
information about our placement systems e.g.
▪ Technical documentation,
▪ Technical information,
▪ Spare parts lists etc.
Registration for the user group is very simple:
► Click on the Register link.
► Fill in the registration form and send it off to us.
Soon afterwards, you will receive your access authorization with USER ID and password.