00196625-03_AI_SX12_PCB_Barcode_de_en.pdf - 第145页
Setting up and Commissioning Running the Cables Installing the PCB Barcode Scanner PCB Barcode LP-Barcode 145 3.2.4.4 Running the Cable at the Mounting Frame ► Pull a plastic bag over the loose cab le ends. This makes it…

Setting up and Commissioning
Installing the PCB Barcode Scanner Running the Cables
144 PCB Barcode LP-Barcode
Inserting the Holder into the Mounting Frame
► Check whether the holder and the scanner can be inserted together into the receptacle on the
mounting frame and whether the connectors can be plugged together. Place the scanner and holder
in the required position in the mounting frame.
The holder is fixed via magnets to the mounting frame.
Cable loop - example of 1D barcode scanner at cross angles and 2D barcode scanner
► Connect the SUB-D connector for the relevant cable set to the SUB-D connector of the barcode
scanner.
CAUTION
Do not get the sets of cables confused with one another.
Make sure that you use the correct set of cables. Take care never to confuse the cable sets for
1D and 2D barcode scanner (e.g. during conversion work). When using a 1D barcode scanner,
you must fit the intermediate adapter (gender changer).

Setting up and Commissioning
Running the Cables Installing the PCB Barcode Scanner
PCB Barcode LP-Barcode 145
3.2.4.4 Running the Cable at the Mounting Frame
► Pull a plastic bag over the loose cable ends.
This makes it easier to thread the cables into the SIPLACE SX later on.
Running the cable at the mounting frame - example with
-
out holders fitted
► Run the cable set along the mounting frame and fix it
with cable ties to the cable clamps (1).
► Prepare the following cable lengths (3) for connection
of the conveyor control and the converter or hub,
measured from the last cable clamp on the mounting
frame (2):
⇨ Length of cable to conveyor control 1: 480 mm
⇨ Length of cable to conveyor control 2: 1000 mm
⇨ Length of cable to converter or hub: 900 mm

Setting up and Commissioning
Installing the PCB Barcode Scanner Preparing the SIPLACE SX
146 PCB Barcode LP-Barcode
3.2.5 Preparing the SIPLACE SX
► End all tasks on the SIPLACE SX and shut down the machine.
► Switch off the machine at the main switch and secure it to prevent unauthorized reactivation.
► Remove the changeover tables from the machine.
► Move the component heads manually to the back.
► Release the conveyor sides, so that these can be adjusted to make room for working.
Access to the conveyor control system
Fitting the option board
Option board with connections and drilled holes
Position of the fixture screw (1)
► Remove the cover from the conveyor control. To do
this, unscrew the relevant fixture screw until you can
take off the cover. Do not remove the screw!
► Lift the cover carefully out of the machine, making
sure that it does not catch on any parts.
You will need to remove both covers on machines
with a dual conveyor.