4-39 4 Making the dispensing stable 5.1.2 Entering the pre-dispensing position T o enter the pre-dispensing XY positions on the dot station, proceed as follows. 1 Set the "Dot Datum" par ameter . The dot datum …

100%1 / 401
4-38
4
Making the dispensing stable
5.1.1 Setting the dot station function
1
Add the dot station function.
1. Press the [Machine] button to open the VmSpec window.
2. Select "Installation Setting" in the tree view to display the "Installation Setting" grid in the main view.
3. Set the "Dot Station" parameter to "A Type" or “B Type”.
Installation Setting
Dot Station parameter setting
Installation Setting Set "Dot Station" to "A Type" or "B Type"
64407-N7-00
4-39
4
Making the dispensing stable
5.1.2 Entering the pre-dispensing position
To enter the pre-dispensing XY positions on the dot station, proceed as follows.
1
Set the "Dot Datum" parameter.
The dot datum indicates the position at which predispensing starts on the dot station.
1. Select the "Dot Station" in the tree view to display the "Dot Station" and "Position" grids in the main
view.
2. Set the X and Y positions in the "Dot Datum" row.
The pre-dispensing position must be set to a position which is 3mm inward from the right edge of the
paper in the X direction and 5mm inward from the edge of the paper in Y direction.
3. Set the Z position in the “Dot Datum” row.
Check the height where the stopper of Head 1 just contacts the paper on the dot station. Then, as
the Z position, enter a value 0.2 mm greater than that height.
Dot station
Pre-dispensing position
Dot station
64408-N7-00
2
Set the "Dot Matrix" parameter.
Set the predispensing pitch and the number of dots in the "Dot Matrix" row.
1. In "Pitch", enter the interval (mm) to automatically predispense on the dot station.
2. In "Amount", enter the number of predispensing dots in Y direction.
Dot station
Predispensing position
Station datum
Dot datum
Dispense area
Diffuser
24mm
45mm
5mm
5mm
3mm
3mm
63405-N7-10
4-40
4
Making the dispensing stable
3
Set the station datum.
Set the left side edge position of the plastic plate to the dot station.
4
In "Size" (X, Y), enter the X and Y sizes of the area where predispense is to be
performed.
Set "24 mm" for X and “45 mm” for Y.
These values should not be changed.
5
Set the feeding timer
In "Timer", enter the period of time during which power is to be supplied to the dot station's paper feed
motor. This period of time means the amount of paper feed. The time can be set to a maximum of 0.50
seconds in steps of 0.05 seconds.
5.1.3 Setting the dot station data
1
Display the dot station data.
Select "Dot Station" in the tree view to display the "Dot Station" grid in the main view.
2
Set the dot station data.
Dot station data
Dot station
1 2 3 54 6
64409-N7-00
1. Max Amount
Divide the total dispense consumption (equivalent to one whole syringe) measured during automatic operation by 1000,
and enter the result in "Max Amount". This parameter is used to issue a warning when the dispensing liquid has run out.
(Max. 99999.99)
For instance, enter "1357.46" if the total dispense consumption is "1357456".
When this value is reached, the warning buzzer will sound and a message will appear. If the machine has the optional
adhesive run-out sensor or if you are not going to use this function, enter "0".
2. Feedback Condition
Enter the number of boards for which recognition feedback is to be performed.
After dispense is completed for the specified number of boards, dot recognition correction will be performed on the next
board according to the predispensing data. (Max. 9999)