1-10 1 Part names and functions 3.3 Dot plate T he dot plate is provided with this machine as standard and is used to correct the dispensing position (XY deviation) after a nozzle is replaced. A remov able ceramic plate …

100%1 / 401
1-9
1
Part names and functions
3.2.3 Narrow-pitch type nozzles
Narrow-pitch type nozzles
Nozzle hole size (A)
63121-N7-00
Nozzle type / Name External view
Dimensions
Applicable parts / Note
A (dia.)
Type 117
Nozzle 1 SHOTø0.4
0.4 1608 size
Type 11D
Nozzle 1 SHOTø0.8
0.8 SOP/QFP
Type 11E
Nozzle 1 SHOTø1.0
1.0 SOP/QFP
Type 11F
Nozzle 1 SHOTø1.3
1.3 Large parts
Type 11G
Nozzle 1 SHOTø1.5
1.5 QFP/PLCC
1-10
1
Part names and functions
3.3 Dot plate
The dot plate is provided with this machine as standard and is used to correct the dispensing position (XY
deviation) after a nozzle is replaced. A removable ceramic plate is used as a board to dispense dots for position
correction.
The function for correcting the dispensing positions using this dot plate is called the “position correction
dispense function”. For more details on this function, refer to “4. Position correction dispense function” in
Chapter 4.
TIP
When the machine is equipped with a dot station, the dot plate is not installed in the machine since the dot station
also serve as a dot plate.
n
NOTE
The dot plate is only used with the “position correction dispense function” and the liquid dispensed on the dot plate
should be wiped away after use. When correcting the dot shape and liquid amount, an optional dot station will be
needed.
Dot plate
Clamp lever
Station datum
Dot datum
6.0mm
6.0mm
6.0mm
6.0mm
88.0mm
48.0mm
Ceramic plate
Stopper
Dot plate reference position
Contacting direction
Contacting position
Contacting direction
63120-N7-20
n
NOTE
When installing the dot plate, bring it in contact with the contacting position in the direction indicated by an arrow
and secure it.
1-11
1
Part names and functions
3.4 Dot station (option)
The dot station is used as a dummy board where the dispenser head performs predispensing, such as in the
following cases:
Dispensing for position correction
Performing a dot feedback to prevent a reduction in the dispensing dot size which may be caused
by a change in the remaining amount of dispensing liquid. (Dispensing amount correction)
Predispensing during dispensing task to stabilize the first dispensing from a head that has not been in
use for a long time. (Automatic predispensing)
A roll of special paper (automatically rolled up) is used as the dummy board on which predispensing is
performed. After a syringe is replaced with a new one, the first dispensing liquid can be dispensed into a liquid
disposal cup. Predispensing is performed on the dot station with the paper held by vacuum.
n
NOTE
For more details on the dot station, see "5. Dot station (option)" in Chapter 4.
Dot station
Dot station main body
Pre-dispensing location (special paper)
Negative pressure indicator
Liquid disposal cup
63109-N7-10
Negative pressure indicator
This indicator displays a negative pressure used to hold the paper by vacuum. The color of the displayed value changes
according to the negative pressure level.
Green: Negative pressure level is appropriate.