YSD_Users_E.pdf - 第241页

5-52 5 Creating the board data 6.1 Creating procedure Pressing the Mark button in the menu button area opens the mark information screen as shown below . Enter the mark name and comment in the upper grid of the screen, a…

100%1 / 401
5-51
5
Creating the board data
6. Creating the mark information
This section describes how to create mark information for fiducial marks used on a board. Mark information
has various parameters for each of the mark names registered. To set these parameters, copy sample data of
a mark with a similar shape from the database and edit only the different parameters.
Mark information parameters
Shape Type
Mark Out Size
(Mark Outline X)
(Mark Area)
(Mark Perimeter)
Mark Type
Database Number
Surface Type
Algorithm Type
Mark Threshold
Tolerance
Search Area XY
Outer Light
Inner Light
Coaxial Light
IR Outer Light
IR Inner Light
Cut Outer Noise
Cut inner Noise
Sequence
Mark Name
Mark Comment
(Mark Type)
• Fiducial
• Badmark
• Fid for Bad
• Dispense Dot
• Height Correction
64529-N7-00
TIP
The displayed parameters vary with the selected "Mark Type" and "Shape Type",
5-52
5
Creating the board data
6.1 Creating procedure
Pressing the Mark button in the menu button area opens the mark information screen as shown below. Enter
the mark name and comment in the upper grid of the screen, and set the parameters in the right lower grid as
explained below.
1
Press the [Mark] button to open the mark information screen.
Mark screen
Step 2Step 1 Step 3
Step 5
Step 4Step 7
64530-N7-00
2
Enter the mark name in the Mark Name column.
Enter a different name for each mark within 19 alphanumeric characters. A space cannot be included
in the name.
3
Enter a comment.
Type any desired comment in the Mark Comment column as necessary. You can omit entering
comments here.
4
Set the parameters.
While selecting the [Basic], [Shape], [Vision] tabs and so forth, set the necessary parameters in the right
lower grid. (See "6.2" to "6.4" in this section.)
TIP
When setting the mark parameters, it is handy to copy sample data of a mark with a similar shape from the database
and edit only the different parameters.
5
Adjust the parameters in the Parts Adjust mode.
Press the [Adjust] button to open the Parts Adjust window that allows you to adjust or check the
parameters of the selected component. (For more details, see “6.5 Mark Adjust mode” in this chapter.)
6
Repeat the above steps for other marks.
Repeat the same procedure from step 2 to register all marks to be used.
7
Save the data.
Press the [Save] button to store the data.
5-53
5
Creating the board data
6.2 Basic parameters
[Database] button
2 1
Mark
Basic parameters
3
4
5
64531-N7-00
1. Mark Type
Select the mark type from the dropdown list.
The item selected here will be displayed on the Mark Type column in the upper grid.
2. Database Number
Shows the database number when the parameter values were copied from the database.
When you want to copy the parameter values from the database, press the [Database] button to open the database list.
Then select the copy source data and press the [Set] button to make a copy.
3. Badmark Mark Rev
Select “Normal” or “Reverse”. When “Normal” is selected, the machine continues operation as long as no badmark is
detected. When “Reverse” is selected, the machine performs work when a badmark is detected.
4. Temperature, +Pressure, -Pressure
Use these fields to make a note.
5. Upper Limit, Lower Limit
Set the upper and lower limits of the range in which the measurement result is effective. Enter these limits in millimeters.