YSD_Users_E.pdf - 第289页
6-20 6 Using the advanced functions [Renumber] tab Parts screen 64621-N7-00 n Sor t par ts in order Renumbers all rows while remo ving blank rows. n Sor t par ts in Feeder Set No. Rearranges the data into the rows with t…

6-19
6
Using the advanced functions
3.5 Renumber
You can sort the data in ascending or descending order by a specified data item.
The items shown on the [Renumber] tab differ depending on which screen is currently
opened.
• When the Board screen is opened:
You can sort the mount, offset, fiducial mark, badmark, pre-dispense and dot dispense data in ascending or descending
order by a specified data item.
• When the Parts screen is opened:
You can renumber all rows while removing blank rows or rearranges the data into the rows with the same number as
feeder set No.
[Renumber] tab
Board screen
64620-N7-00
n
Order
This is the priority level used to sort the data. Up to 10 priority levels can be specified.
n
Item
Select the item by which you want to sort the data. The selectable items are displayed in the drop-down list that appears
by double-clicking the cell.
n
Direction
Select "Upper" to sort the data in ascending order or "Lower" to sort in descending order.
n
[Renumber] button
Pressing the [Renumber] button sorts the data according to the conditions you selected.
n
NOTE
When no data rows are selected in the upper grid, all data rows are sorted.

6-20
6
Using the advanced functions
[Renumber] tab
Parts screen
64621-N7-00
n
Sort parts in order
Renumbers all rows while removing blank rows.
n
Sort parts in Feeder Set No.
Rearranges the data into the rows with the same number as feeder set No.

6-21
6
Using the advanced functions
4. Adjustment
4.1 Dispensing test (Adjustment screen)
This section describes how to perform a dispensing test and check the dot area on the adjustment screen.
When adjusting the air pressure before starting production or during production, see “2. Dispensing test
function” in Chapter 4.
c
CAUTION
The dispense test does not work with normal production boards.
If you are going to perform the dispense test on a board, use the test board (KV6-M3801-10X) supplied with the
machine.
1
Open board data.
Press the [Board] button on the Setup screen.
2
Press the [Utilities] button.
The machine adjustment program starts.
[Utilities] button
[Utilities] button
64622-N7-00
3
Enter the machine adjustment program.
Select “Operator” from the User drop-down list and press the [OK] button.
Machine adjustment program
User drop-down list
64623-N7-00