YSD_Users_E.pdf - 第73页
2-13 2 Basic operation 5. [Left] button, [Right] button Rotates the convey or motor in the left or right direction at high speeds. 6. [Low Left] button, [Low Right] button Rotates the convey or motor in the left or right…

2-12
2
Basic operation
2.3 Unit screen
This section describes the manual operation buttons on the Unit screen.
n
Manual conveyor operation
Conveyor manual buttons
3
1
4
2
5
6
7 8 9 10 11
64230-N7-00
1. [Convey Out] button
Releases the board clamp and moves the board to the exit stopper.
2. [Convey In] button
Moves the board from the entrance or standby position and clamps it at the set position.
3. [Width] button
Use this button to adjust the conveyor width to match the width of boards to be produced.
Pressing this button displays the "Conveyor Width" dialog box. Check the conveyor width and press the [OK] button. The
conveyor rail automatically changes to the specified width.
"Conveyor Width" dialog box
62231-N7-00
c
CAUTION
When adjusting the conveyor width, be careful so that the conveyor rails do not touch the push-up pins and other
conveyor units.
4. [Axis] button
Use this button when moving each axis manually.
Pressing this button displays the "Move Axis" screen that allows you to manually move each axis at a specified step stroke
with the arrow buttons or to a specified position with the [PTP] buttons.

2-13
2
Basic operation
5. [Left] button, [Right] button
Rotates the conveyor motor in the left or right direction at high speeds.
6. [Low Left] button, [Low Right] button
Rotates the conveyor motor in the left or right direction at low speeds.
7. [Exit Stopper] button
Raises or lowers the exit stopper that stops a board at the conveyor exit.
8. [Push Up] button
Pressing this button opens a dialog box for entering board thickness. Check or enter the board thickness to clamp the
board by pushing it up from the bottom (underside).
9. [Board Clamp] button
Clamps the board by pushing up its edges from the bottom (underside).
10. [Main Stopper] button
Raises or lowers the main stopper that stops a board in the clamp position on the conveyor.
11. [Entrance Stopper] button (Option)
Use this button to stop the incoming board at the standby position.
"Move Axis" screen
1
2
4
5
6
7
3
64232-N7-00
Button name Function
1 Zoom in/out (+, -) Zooms in or out the image. (16 times to 1/16 times)
2 Mark Light Allows changing mark lighting manually. Using this button does not affect data.
3 PTP
Displays the "PTP" dialog box that allows directly specifying the position where you
want to move the selected axis.
4 Step Mode
When this button is pushed in, the selected axis can be moved in "step mode (inching
mode)" with the arrow buttons at a specified step stroke (inching stroke).
5 Arrow Use these buttons to move the selected axis in the desired direction.
6 Head Select Select the head to operate (ZR axis only). All heads rotate with the R-axis.
7 Brake
Use this button when you want to release the brake during emergency stop. (PU axis
only)
The brake is automatically released when the servo is turned on.

2-14
2
Basic operation
n
Manual head operation
[Unit] – [Head] screen
1
Target temperature
and current temperature
64233-N7-00
1. [Blow] button
Pressing each button dispenses adhesive. To stop dispensing, press the button again.