CM602all_EJM8AESM_Service Manual.pdf - 第275页
Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles) Remarks Item Press [Xyplane cal teach]. The jig is clamped in the Z direction. The AF head recognizes the dots on the jig. Then the AR head recognizes them.…

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Press [XY plane cal].
Conveyor width is
adjusted to 460 mm
automatically.
Press [Jig setting].
The AF head moves away.
Place the jig on the conveyor.
Place the jig by hand, pressing the
reference-mark corner of the jig against
the fixed conveyor and the board
stopper.
Press [Jig adjust].
The jig is clamped in the Y direction.
(Option)
Check that the jig is
locked once it is clamped
in the Y direction.
3
4
1
2
Item
EJM8A-E-SMA040306-A01-00
Page 4-3-6-2

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Item
Press [Xyplane cal teach].
The jig is clamped in the Z direction.
The AF head recognizes the dots on the
jig. Then the AR head recognizes them.
Press [Jig remove].
Both AF and AR heads move away.
Once they finish moving away, remove
the jig.
Press the "Return" key.
Press [Run].
7
8
5
6
EJM8A-E-SMA040306-A01-00
Page 4-3-6-3

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Item
Change stages.
Select Stage B.
Carry out Steps 2 to 6 in the same way
as Stage A.
Check the data after teaching.
The offsets are entered automatically into the screen below:
Offset range:
X: -0.5 mm to +0.5 mm
Y: -0.5 mm to +0.5 mm
11
9
10
EJM8A-E-SMA040306-A01-00
Page 4-3-6-4