CM602all_EJM8AESM_Service Manual.pdf - 第493页
Item Put the feeder cover back on. 5 Phillips screwdriver #2 Screw M4 2 pcs. Remarks Tool/Spec/Installation Machinery Part Replacement Light Transfer-Head Assembly (3-nozzle type) EJM8A-E-SMA050404-A01-00 Page 5-4-4-3

Machinery Part Replacement
Light Transfer-Head Assembly (3-nozzle type)
Tool/Spec/Installation
Tool/Spec/Installation
4
Remarks
Phillips screwdriver #2
Screw M4 2 pcs.
3
Apply grease to the holder.
2
1
Item
Remove the hook from the nozzle clamp.
Remove the feeder cover.
Fit the clamp hook.
Tool/Spec/Installation
Grease
Tool/Spec/Installation
EJM8A-E-SMA050404-A01-00
Page 5-4-4-2

Item
Put the feeder cover back on.
5
Phillips screwdriver #2
Screw M4 2 pcs.
Remarks
Tool/Spec/Installation
Machinery Part Replacement
Light Transfer-Head Assembly (3-nozzle type)
EJM8A-E-SMA050404-A01-00
Page 5-4-4-3

Machinery Part Replacement
Z Unit (3-nozzle type)
Assembly/Adjustment
This section describes the procedures for replacing the stroke end sensor
Stroke End Sensor Replacement5-5-1
Min.
Phillips screwdriver #1
Phillips screwdriver #2
Allen key 2.5 mm
Allen key 3 mm
Caliper
None
• Tools
• Jigs
Removal/Disassembly
10
Min.
10
Min.
Kg
Teaching Total Time Part Weight
Min.
20
Z Unit (3-nozzle type)
5-5
Caution
Danger
Warning
EJM8A-E-SMA050501-A01-00
Page 5-5-1-1