Maintenance Adjustment Light Transfer-Head Assembly(3-nozzles) Remarks Press [Lead checker]. Select the desired stage. Press [Unlock] and [Jig setting] simultaneously. Set the jig onto Head 3. Press [Unlock] and [Z teach…

100%1 / 1093
Maintenance Adjustment Light Transfer-Head Assembly(3-nozzles)
Tools
None
Jig
Lead checker positioning
jig FM-1137
4-3-11      Lead Checker
This section describes the procedures for entering the offset for the origin of the chip recognition camera theta axis.
Caution
Dange
r
Warning
Assembly
Ad
j
ustmen
t
min.
Teaching
10min.
Total Time Weight of
Part
Removal
Disassembl
y
min.
10min.
kgs
EJM8A-E-SMA040311-A01-00
Page 4-3-11-1
Maintenance Adjustment Light Transfer-Head Assembly(3-nozzles)
Remarks
Press [Lead checker].
Select the desired stage.
Press [Unlock] and [Jig setting] simultaneously.
Set the jig onto Head 3.
Press [Unlock] and [Z teach] simultaneously.
Head 3 moves to the lead checker and Z
(between the lead checker and the jig) is
measured automatically.
4
1
Item
2
3
EJM8A-E-SMA040311-A01-00
Page 4-3-11-2
Maintenance Adjustment Light Transfer-Head Assembly(3-nozzles)
Remarks
Item
Press [Unlock] and [XY teach] simultaneously.
Starting from the point at which the Z
teaching is finished, X and Y are
measured automatically.
Press [Unlock] and [Jig remove] simultaneously.
Remove the jig from
Head 3.
Press the "Return" key.
Press [Unlock] and [Run] simultaneously.
The selected head returns to the origin.
5
6
7
8
EJM8A-E-SMA040311-A01-00
Page 4-3-11-3