CM602all_EJM8AESM_Service Manual.pdf - 第656页
Machinery Part Replacement This section describes the procedures for removing the upper frame and the Z-axis unit. Tools Allen key 3 mm Nipper Magic marker Jig None 12-Nozzle Head Unit 5-10-9 Removing the Upper Frame and…

Machinery Part Replacement
Remark
12-Nozzle Head Unit
Item
Turn on the power and air supply.
カバー達
A
d
j
ustment
Teaching
Head Camera Adjustment (Focus and θ)
Board Recognition Camera XY Origin
Offset
Z-axis Origin Offset
Chip Recognition Camera, θ-axis Origin
Offset
Width Adjusting-axis Origin Offset
Mount Height and Board Positioning
XY Plane Calibration
Pickup Position
Light Intensity
Nozzle Change Position
Mount Position
Section 5-11-1
Section 5-11-2
Section 5-11-3
Section .5-11-4
Section 5-11-5
Section 5-11-6
Section 5-11-7
Section 5-11-8
Section 5-11-9
Section 5-11-10
Section 5-11-11
27
28
1
2
EJM8A-E-SMA051008-A01-00
Page 5-10-8-9

Machinery Part Replacement
This section describes the procedures for removing the upper frame and the Z-axis unit.
Tools
Allen key 3 mm
Nipper
Magic marker
Jig
None
12-Nozzle Head Unit
5-10-9 Removing the Upper Frame and the Z-axis Unit
Caution
Dange
r
Warning
EJM8A-E-SMA051009-A01-00
Page 5-10-9-1

Machinery Part Replacement
Remark
Turn off the power and air supply.
Remove the head.
See "12-Nozzle-Head-Unit
Replacement."
Section 5-10-1
Remove the tube and the cable tie.
12-Nozzle Head Unit
3
2
Item
1
Remove the two tubes.
Disconnect the connectors
CN35 and 36
Disconnect the connectors
CN39 and 40
<Left side>
1
2
EJM8A-E-SMA051009-A01-00
Page 5-10-9-2