CM602all_EJM8AESM_Service Manual.pdf - 第527页
Machinery Part Replacement Remarks Item Z Unit (3-nozzle type) Connect the valve connector. Secure the cables with cable ties. 2-000170 Nipper Cable tie Put the head cover back on. Phillips screwdriver #1 Phillips screwd…

Machinery Part Replacement
Remarks
Item
Z Unit (3-nozzle type)
Remove a set of manifolds. Replace the valves.
One set consists of three valves. Allen key 2.5 mm
Screw M3 6 pcs.
Put a new set of manifolds in position.
Allen key 3 mm
Screw M4 2 pcs.
Connect the vacuum and the air tubes.
Connect the vacuum tube to the vacuum sensor.
2-000004
12
9
10
11
EJM8A-E-SMA050506-A01-00
Page 5-5-6-4

Machinery Part Replacement
Remarks
Item
Z Unit (3-nozzle type)
Connect the valve connector.
Secure the cables with cable ties.
2-000170
Nipper
Cable tie
Put the head cover back on.
Phillips screwdriver #1
Phillips screwdriver #2
Screw M3 2 pcs.
M4 2 pcs.
Put the feeder cover back on.
カバー達
Phillips screwdriver #2
Screw M4 2 pcs.
13
14
15
16
EJM8A-E-SMA050506-A01-00
Page 5-5-6-5

Machinery Part Replacement
Remarks
Item
Z Unit (3-nozzle type)
Switch on the main power.
Check the valve function.
18
When Vacuum Pump ON, Vacuum ON and Mount Blow OFF, vacuum should be created at the end of the nozzle.
When Vacuum Pump ON, Vacuum OFF and Mount Blow ON, the end of the nozzle should blow.
17
EJM8A-E-SMA050506-A01-00
Page 5-5-6-6