CM602all_EJM8AESM_Service Manual.pdf - 第308页
Maintenance Adjustment Light Transfer-Head Assembly(3-nozzles) ・ Tools None ・ Jig Lead checker positioning jig FM-1137 4-3-11 Lead Checker This section describes the procedures for entering the offset for the origin of t…

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Item
Press [Unlock] and [Run] simultaneously.
The offsets are entered automatically into the screen below:
If a large negative value is entered into
Offset B, check:
1. that a vacuum ring is suspended by two
extension springs.
2. that the spline shaft slides smoothly.
Manually enter "F1" and
"F2" values.
F1: 4.0 N to 6.0 N
F2: 15.0 N to 25.0 N
Once the loads above are
entered, offsets will be
calculated automatically.
A: 8.0 to 9.5
B: 0.0 to 15.0
28
27
EJM8A-E-SMA040310-A01-00
Page4-3-10-10

Maintenance Adjustment Light Transfer-Head Assembly(3-nozzles)
・Tools
None
・Jig
Lead checker positioning
jig FM-1137
4-3-11 Lead Checker
This section describes the procedures for entering the offset for the origin of the chip recognition camera theta axis.
Caution
Dange
r
Warning
Assembly
Ad
j
ustmen
t
min.
Teaching
10min.
Total Time Weight of
Part
Removal
Disassembl
y
min.
10min.
kgs
EJM8A-E-SMA040311-A01-00
Page 4-3-11-1

Maintenance Adjustment Light Transfer-Head Assembly(3-nozzles)
Remarks
Press [Lead checker].
Select the desired stage.
Press [Unlock] and [Jig setting] simultaneously.
Set the jig onto Head 3.
Press [Unlock] and [Z teach] simultaneously.
Head 3 moves to the lead checker and Z
(between the lead checker and the jig) is
measured automatically.
4
1
Item
2
3
EJM8A-E-SMA040311-A01-00
Page 4-3-11-2