Copyright © ViT rox All Rights Reserved . Machine Setting (Machine) 67 Three Limit XY position for gantry limit Level of step to move the gantry Current V alue position of gantry Stage Limit position of gantry Figure 58:…

Copyright © ViTrox All Rights Reserved.
Machine Setting (Calibration)
This should only be used in pre-reflow setup.This calibration is done to inspect components at different
positions in the camera's field of view. It calculates offsets to compensate for the curvature of the lens. It is
necessary to carry out this calibration to ensure that positional measurement is accurate.The Position In
View test should be done when pixel size is changed, lens is refocused, or lighting intensities change
significantly, or alternatively when an entire optical setup is due.
66
Note: 3D Calibration Setting to perform the calibration when the pixel size is changed, lens refocused or lighting intensities
change significantly and perform calibration maintenance.
Figure 57: 2D and 3D Calibration Setting

Copyright © ViTrox All Rights Reserved.
Machine Setting (Machine)
67
Three Limit XY position
for gantry limit
Level of step to move the gantry
Current Value position of gantry
Stage Limit position of gantry
Figure 58: Machine Setting for Gantry

Copyright © ViTrox All Rights Reserved.
Machine Setting (PLC Configuration)
68
Figure 59: PLC Configuration