VI User Manual.pdf - 第345页
Superviseur Vision 2007 4.10 User Manua l Rev 01 13 - 1 Chapter 13 Superviseur The Superviseur software is the link between the AOI system and the repair station. It records all data from both machines in a d a tabase. T…

Optimization
12 - 26 Vision 2007 4.10 User Manual Rev 01
F Click on the button near the profile to zoom on it.
Tolerances (
A), in black, are calculated by statistic.
You can move tolerances manually to include minimum and maximum profiles (If
you are absolutely sure that all your lead/joint are good).
In the window belove, save the library on the disk, either with a same name, or with
an other name.
Click on
Finish
button.
12.4.3 Profiler Automatic Setting default values
Open the Defaultvalue.ini file to access the Auto settings (Profiler and Lead to Lead) pa-
rameters.
12.4.3.1 Profiler
12.4.3.2 Lead to lead
[Profiler(Auto settings)]
Xmin_Algoname=3
Xmax_Algoname=3
[Lead2Lead(Auto settings)]
Xmin_Algoname=3
Xmax_Algoname=3
Profiler
™
Automatic Setting

Superviseur
Vision 2007 4.10 User Manual Rev 01 13 - 1
Chapter 13
Superviseur
The Superviseur software is the link between the AOI system and the repair station.
It records all data from both machines in a database. The database can either be an Access or MS-SQL
Server database (for more information see chapter Database).
The supervisor provides quick information display such as:
The inspection results of all the produced boards,
The status of all the connected machines.
As the supervisor software holds all production data, it may be used to export them to an external system. In
that case, it calls a communication module which uses a specified protocol (for example: IPC2547).
Connecting and monitoring stations
You can link up to 24 stations (AOI systems and repair stations).
For example:
Vi-5000_1 and repair station_1 for line 1
Vi-5000_2 and repair station_2 for line 2
Vi-5000_3 and repair station_3 for line 3
Vi-5000_4 and repair station_4 for line 4
Vi-5000_5 and repair station_5 for line 5
In the example above, 6 stations (3 AOI systems and 3 repair stations) are linked to the supervisor.

Superviseur
13 - 2 Vision 2007 4.10 User Manual Rev 01
13.1 Superviseur configuration
The first time the software is launched, the following wizard is executed in order to help the user to
configure it properly.
You can also access these settings using the configuration menu in the software.
13.1.1 Directory setting
Select the Picture storage directory
(A). It corresponds to the location where
the AOI system will save pictures of de-
fects.
Select the
Supervisor clients file storage
directory
(
B
).
In both cases, you can select the direc-
tory by clicking on the icon.Then
click on Next.
13.1.2 Database setting
Selct your working database.
Select the database type (Access or
SQL) (A).
If you choose Access, enter the data-
base filename (B). Then, click on Next.
You must be administrator when starting supervisor software for the 1st time (for database
settings).
You must be administrator for
the database settings (System
DSN registration).
A
B
A
B