VI User Manual.pdf - 第401页

.ini files Vision 2007 4.10 User Manua l Rev 01 A - 25 A.5.10 QFP tool: body detection INI section : [QFP(Body)] A.5.1 1 QFP to ol: leads detection INI section : [QFP(End of leads)] Mark Key na me Initial value Min value…

100%1 / 412
.ini files
A - 24 Vision 2007 4.10 User Manual Rev 01
A.5.9 SO tool: solder joint and bridge detection
INI section : [SO(Joint & Bridge)]
Mark Key name Initial value Min value Max value
A Contrast 50 0 255
B Filter Half Size 0.08 0.03 1
C Min threshold(0,255) 0 0 255
D Max threshold(0,255) 200 0 255
E Enable joint(0,1) 1 0 1
F Enable Bridge(0,1) 1 0 1
G Search angle step 0.1 0.01 10
A
F
B
C
E
D
Library default values
.ini files
Vision 2007 4.10 User Manual Rev 01 A - 25
A.5.10 QFP tool: body detection
INI section : [QFP(Body)]
A.5.11 QFP tool: leads detection
INI section : [QFP(End of leads)]
Mark Key name Initial value Min value Max value
A Tolerance 0.5 0 2
B Contrast 30 0 255
C Filter half size 0.08 0.03 1
Mark Key name Initial value Min value Max value
A Contrast 15 0 255
B Filter half size 0.12 0.03 1
A
B
C
A
B
Library default values
.ini files
A - 26 Vision 2007 4.10 User Manual Rev 01
A.5.12 QFP tool: solder joint and bridge detection
INI section : [QFP(Joint & Bridge)]
Mark Key name Initial value Min value Max value
A Contrast 50 0 255
B Filter Half Size 0.08 0.03 1
C Min threshold(0,255) 0 0 255
D Max threshold(0,255) 200 0 255
E Enable joint(0,1) 1 0 1
F Enable Bridge(0,1) 1 0 1
A
F
B
C
E
D
Library default values