2.5.1 What does ESD mean?
Almost all of the modules in use today are equipped with highly integrated MOS blocks and com
-
ponents. The manufacturing techniques used mean that these electronic components are ex
-
tremely sensitive to overvoltage and thus to electrostatic discharge.
The abbreviation for such modules is 'ESD' (Electrostatic Sensitive Device). ’ESD’ is used inter
-
nationally. The following symbol on cabinet typeplates, racks or packaging indicates that compo
-
nents which are sensitive to electrostatic discharge have been used and that the modules
concerned are also touch-sensitive.
ESDs can be destroyed by voltages and power levels that are far below the level
that can be perceived by humans. Such voltages occur if a person touches a com
-
ponent or module without earthing themselves. Components that are exposed to
such overvoltages do not generally appear to be defective immediately - incorrect
behavior starts after the component or module has been in operation for some time.
2.5.2 Important measures to protect against static charging
Most plastics can easily become charged and must therefore be kept away from at-risk com
-
ponents.
Always ensure that people, the workplace and packaging are safely earthed when handling
electrostatic sensitive components.
2 Operational safety Assembly and Instruction Manual
2.5 ESD guidelines Shuttle Extension Edition 11/2018
36
2.5.3 Handling ESD modules
Do not touch electronic modules unless it is absolutely essential to do so in order to carry out other
work. If it is necessary, make sure that you do not touch the pins or printed conductors when you
pick up flat modules.
Do not touch components unless
you are constantly earthed by an ESD wrist strap or
you are wearing ESD shoes or ESD shoe earthing strips on an ESD floor.
Always discharge yourself before you touch an electronic module. To do this, simply touch a con
-
ductive and earthed object immediately before you touch the module (such as unpainted parts of
a switch cabinet, a water pipe, etc.).
Do not allow modules with chargeable and highly insulating materials to touch one another, e.g.
plastic films, insulating table surfaces or items of clothing made from synthetic fibers.
Always place the modules on a conductive surface (table with an ESD coating, conductive ESD
foam, ESD bag or container).
Do not move the assemblies near to data view devices, monitors or television units. Keep a min
-
imum distance of > 10 cm to monitors.
2.5.4 Measurements and modifications to ESD modules
Do not take measurements on the modules unless the following conditions are fulfilled:
the measuring device is earthed (e.g. via PE conductors) or
you discharge the measuring head just before taking measurements with a potential-free
measuring device (e.g. by touching an unpainted metal part of the controller casing).
Always use an earthed soldering iron if you carry out any soldering work.
2.5.5 Dispatching ESD modules
Always store modules and components in conductive packaging (e.g. metallized plastic bags
or metal sleeves) and dispatch them in conductive packaging.
If the packaging is not conductive, place the modules in a conductive envelope before pack
-
aging. Use conductive expanded rubber, ESD bags, domestic aluminum foil or paper, for
example. NEVER use plastic bags or film. 2
If the module has integral batteries, ensure that the conductive packaging does not touch or
short-circuit the battery terminals and, if necessary, first cover the terminals with insulating
tape or material.
Assembly and Instruction Manual 3 Assembly on the SIPLACE TX
Shuttle Extension Edition 11/2018 3.1 Scope of delivery
37
3 Assembly on the SIPLACE TX
3.1 Scope of delivery
Shuttle extension: Item no.:588508-xx
Transport rail position 281
Assembly kit for mechanical connection: Item no.:
Shuttle extension - holder output conveyor back and front Item no.: 03148418-xx
Shuttle extension - holder input conveyor back and front Item no.: 03148410-xx
2 x SMEMA Cable - for one shuttle extension: Item no.:03152800-xx
One SMEMA cable for each lane.
1 x CAN Bus cable for one shuttle extension: Item no.:03133551-xx
1 x Power interface cable to SIPLACE TX: Item no. 03123550-xx