3 Assembly on the SIPLACE TX Assembly and Instruction Manual 3.4 Electrical connections Shuttle Extension Edition 11/2018 50 3.4.2.3 CAN cable connections for special configuration Fig. 3.4 - 3 CAN cable connection s for…

100%1 / 284
Assembly and Instruction Manual 3 Assembly on the SIPLACE TX
Shuttle Extension Edition 11/2018 3.4 Electrical connections
49
3.4.2.2 Connections
The shuttle extension supports two configurations: upstream and downstream, the wiring and
jumper settings are specified as follows:
3
For special configurations where two shuttle extensions are link to a single SIPLACE TX machine,
the CAN cable and TSP 420 jumper setting will be configure as per below.
3
Upstream configurations Downstream configurations
Power connection to TX -X15.S1 -X15.S2
CAN Bus connection to TX CAN3.EXT CAN3.EXT
Power connection to TX X50 X50
CAN bus connection to shuttle X52 X52
SMEMA connection to TX -XL1 and XL2 upstream -XL1 and XL2 upstream
SMEMA connection to shuttle -XL1-DS and XL2-DS (down
-
stream)
-XL1-US and XL2-US
(Upstream)
TSP 420 jumper setting JP1 pin 2 and 3 is shorted
JP2 pin 1 and 2 is shorted
JP1 pin 2 and 3 is shorted
JP2 pin 1 and 2 is shorted
CAN termination connector re
-
moved from CAN3.EXT
Plugged into -X1* (CAN ca
-
ble: upstream)
Plugged into -X1* (CAN ca
-
ble: downstream)
CAN cable IDC connector Upstream configurations Downstream
configurations
-X1 -X1*(cable: downstream) CAN3.EXT (TX)
-X1* CAN termination connector
removed from CAN3.EXT
-X1 (cable: upstream)
-X52 -X52 (shuttle upstream) -X52 (shuttle upstream)
TSP 420 jumper setting
JP1 pin 2 and 3 is shorted
JP2 pin 1 and 2 is shorted
JP1 pin 2 and 3 is shorted
JP2 pin 1 and 2 is shorted
3 Assembly on the SIPLACE TX Assembly and Instruction Manual
3.4 Electrical connections Shuttle Extension Edition 11/2018
50
3.4.2.3 CAN cable connections for special configuration
Fig. 3.4 - 3 CAN cable connections for special configuration
Assembly and Instruction Manual 4 Assembly on the SIPLACE SX V2
Shuttle Extension Edition 11/2018 4.1 Scope of delivery
51
4 Assembly on the SIPLACE SX V2
4.1 Scope of delivery
Extension kit shuttle on SX2: Item no.:03167757-xx
Power cable to shuttle extension: Item no.:03133550-01-xx
CAN cable to shuttle extension: Item no.:03133551-xx
Connection cable to SX2 shuttle opt: Item no.:03170059-xx
4.2 Assembly kit and mechanical connection
There are currently no plans for a mechanical connection between the SIPLACE SX and the shut
-
tle extension. The shuttle extension is positioned at the SIPLACE so that the board can be trans
-
ported through the PCB conveyor.
Push a board through the PCB conveyor and check the transition point between the shuttle
extension and the SIPLACE SX.
It must be possible to push the board through easily and with no resistance.