A -4 Appendix A - Material Safet y Information A. 3 MSDS M ol y - Graph® Extreme Pressu re Multi - Purpose Grease Section 1: Product & Compan y Identification Product Name : Moly - Graph® Extrem e Pr essur e Mu lti -…

100%1 / 208
Appendix A - Material Safety Information A-3
MSDS - MULTEMP PS NO 2-A 07-350 (Continued)
SECTION VII - Precautions for Safe Handling and Use
Steps if Material Released/Spilled
TRANSFER BULK OF MIXTURE INTO ANOTHER
CONTAINER. ABSORB RESIDUE W/ AN INERT
MATERIAL SUCH AS EARTH, SAND, &
VERMICULITE. SWEEP UP & DISPOSE SOLID
WASTE IN ACCORDANCE W/ LOCAL, STATE &
FED REGS
Waste Disposal Method
DISPOSE OF IN ACCORDANCE W/ STATE,
LOCAL & FED REGS. INCINIRATE IN ACCORD.
W/ APPLICABLE REGS. MATERIAL MAY BE
RECOVERED & RECYCLED
Handling and Storage Precautions
KEEP CONTAINER CLOSED UNTIL READY FOR
USE. STORAGE AWAY FROM FIRE SOURCE OR
SUNLIGHT & IN COOL DRY AREA
Other Precautions
DO NOT USE PRESSUE TO EMPTY
CONTAINER. WHEN EMPTY, CONTAINER MAY
HAVE VAPOR OR PRODUCT RESIDUE. DO NOT
CUT, PUNCTURE OR WELD ON OR NEAR THE
DRUM
SECTION VIII - Control Measures
Respiratory Protection
GOOD VENTILATION SHOULD BE SUFFICIENT
Ventilation
GOOD GENERAL VENT. SHOULD BE
SUFFICIENT
Protective Gloves
RUBBER OR PLASTIC OIL RESISTANT
Eye Protection
CHEMICAL SAFETY GOGGLES & IF HANDLED
HOT, FULL FACE SHIELD
Other Protective Equipment
NONE
SECTION IX - Label Data
Protect Eye
NO
Protect Skin
NO
Protect Respiratory
NO
Chronic Indicator
UNKNOWN
Contact Code
UNKNOWN
Fire Code
UNKNOWN
Health Code
UNKNOWN
React Code
UNKNOWN
SECTION X - Transportation Data
SECTION XI - Site Specific/Reporting Information
Volatile Organic Compounds (P/G)
0
Volatile Organic Compounds (G/L)
0
SECTION XII - Ingredients/Identity Information
Ingredient #
01
Ingredient Name
*REFINED MINERAL OIL
CAS Number
101316727
Percent
25
A-4 Appendix A - Material Safety Information
A.3 MSDS Moly-Graph® Extreme Pressure Multi-Purpose Grease
Section 1: Product & Company Identification
Product Name: Moly-Graph® Extreme Pressure Multi-Purpose Lithium Grease
Product Number(s): SL3141, SL3144, SL3145, SL3146, SL3330, 8SL3141
Manufactured By:
CRC Industries, Inc.
885 Louis Drive
Warminster, PA 18974
General Information
Technical Assistance
Customer Service
24-Hr Emergency (CHEMTREC)
(215) 674-4300
(800) 521-3168
(800) 272-8963
(800) 424-9300
Section 2: Hazards Identification
Emergency Overview
Appearance & Odor: Grey semi-solid to solid grease with a faint petroleum odor
As defined by OSHA’s Hazard Communication Standard, this product is nonhazardous.
Potential Health Effects:
EYE: May cause irritation.
SKIN: Repeated or prolonged contact can result in drying of the skin.
INHALATION: Heating can generate vapors that may cause respiratory irritation, nausea
and headaches. Inhalation hazard at room temperature is unlikely due to
the low volatility of this product.
INGESTION: Can cause stomach ache and vomiting. Main hazard, if ingested, is
aspiration into the lungs and subsequent pneumonitis.
CHRONIC EFFECTS Unknown
TARGET ORGANS: None known
Medical Conditions Aggravated by Exposure
Skin or respiratory conditions
See Section 11 for toxicology and carcinogenicity information on product ingredients.
Appendix A - Material Safety Information A-5
Product Name: Moly-Graph® Extreme Pressure Multi-Purpose Lithium Grease
Product Number (s): SL3141, SL3144, SL3145, SL3146, SL3330, 8SL3141
Section 3: Composition/Information on Ingredients
COMPONENT CAS NUMBER % BY Wt.
Hydrotreated heavy naphthenic distillates 64742-52-5 70 - 90
Lithium 12-hydroxystearate 7620-77-1 5 - 10
Zinc, dithiophosphate di-C1-14-alkyl esters 68649-42-3 0.5 - 1.5
Molybdenum sulfide 1317-33-5 0.2 - 1
Graphite 7782-42-5 0.2 - 1
Section 4: First Aid Measures
Eye Contact: Immediately flush with plenty of water for 15 minutes. Call a physician if irritation
persists.
Skin Contact: Remove contaminated clothing and wash affected area with soap and water.
Call a physician if irritation persists. Wash contaminated clothing prior to re-use.
Inhalation: Remove person to fresh air. Keep person calm. If not breathing, give artificial
respiration. If breathing is difficult give oxygen. Call a physician.
Ingestion: Do not induce vomiting. Seek medical attention.
Note to Physicians:
None available
Section 5: Fire-Fighting Measures
Flammable Properties: This product is nonflammable.
Flash Point: >400F (COC) Upper Explosive Limit: 7.0
ND Lower Explosive Limit: 0.9
Suitable Extinguishing Media: CO2, dry chemical, sand, dolomite, alcohol resistant foam, water spray
Products of Combustion: Oxides of carbon. Sulfur.
Protection of Fire-Fighters: Firefighters should wear self-contained, NIOSH-approved breathing
apparatus for protection against suffocation and possible toxic
decomposition products. Proper eye and skin protection should be
provided. Use water spray to keep fire-exposed containers cool and to
knock down vapors which may result from product decomposition.
Avoid water in straight hose stream as it will scatter and spread fire.