编带机说明书-含图纸ttm402.pdf - 第110页

5-12 TM-403 User’s Guide Configure Inspection D292105.16c.fm 5. The Image Optimization window will open. Select the T rigger Options button on the right. Step 2: Vision Setup CONFIGURE COMPUTER

100%1 / 298
D292105.16c.fm Configure Inspection
Chapter 5: Setup 5- 11
2. Click Trigger ON, then center a part under the camera.
3. Select or create a program from the Program drop-down menu. A yellow Selection
Box will appear over the part image.
4. Click NAVI Sensor Setup.
Step 2:
Vision
Setup
CONFIGURE
COMPUTER
5-12 TM-403 User’s Guide
Configure Inspection D292105.16c.fm
5. The Image Optimization window will open.
Select the Trigger Options button on the right.
Step 2:
Vision
Setup
CONFIGURE
COMPUTER
D292105.16c.fm Configure Inspection
Chapter 5: Setup 5- 13
Adjust Trigger Options to External Trigger with a 0ms Trigger Delay.
6. Select the Brightness Adjustment button on the right
Set the Imaging Mode to High Gain, then click the Automatic Brightness
Adjustment button. Adjust the Exposure Time as needed to achieve the best
contrast between the laser mark and the part.
Step 2:
Vision
Setup
CONFIGURE
COMPUTER