编带机说明书-含图纸ttm402.pdf - 第165页

D292105.9b.fm System Alarm Messages Chapter 7: Troubleshooting 7-9 P ar t Lost System Alarm If a part falls o ff the nozzle and is lost dur ing the pick process, the Part Lost system alarm will be activated. When this ha…

100%1 / 298
7-8 TM-403 User’s Guide
System Alarm Messages D292105.9b.fm
Empty Nest System Alarm
If the Part Present Sensor does not see a part in the Nest, the system will time out and the Empty
Nest system alarm will be activated. When this happens, operation stops, a beep sounds, and a
warning appears on the HMI.
To clear the Empty Nest Alarm, ensure there are parts in the linear track and it is feeding properly
with no jams. If that does not resolve the problem, adjust the linear vibratory amplitude as
needed.
When the Bowl Feeder is ready for operation, press CONTINUE to clear the alarm and resume
operation.
D292105.9b.fm System Alarm Messages
Chapter 7: Troubleshooting 7-9
Part Lost System Alarm
If a part falls off the nozzle and is lost during the pick process, the Part Lost system alarm will be
activated. When this happens, operation stops, a beep sounds, and a warning appears on the
HMI.
To clear the Part Lost System Alarm, check the Vacuum Sensor to ensure it is set correctly.
Ensure the correct Nozzle Tip for the part that is being picked is installed. Check the nest to
ensure there is no part jam. Finally, check the Pick Position to ensure it is centered correctly.
Adjust as necessary.
When the Bowl Feeder is ready for operation, press CONTINUE to clear the alarm and resume
operation.
7-10 TM-403 User’s Guide
System Alarm Messages D292105.9b.fm
No Part to Place System Alarm
If the user attempts to place a part in tape when there is no part on the Nozzle, the No Part To
Place System Alarm will be activated. When this happens, operation stops, a beep sounds, and
a warning appears on the HMI
To clear the No Part To Place System Alarm, pick a part then press CONTINUE to clear the
alarm and resume part placement.