Safety Features D292105.2a.fm ix Reset Button The TM-402’ s blue Reset button is located on the left side of the machine above the Emergency S top Switch. When the machine is powered up, it is au tomatically placed into …

Safety Features D292105.2a.fm viii
Safety Features
Main Power Switch
The Main Power Switch is located on the right side
of the machine. Turning the switch to the right
turns power ON. Turning the switch back to the left
turns the power OFF.
When the Main Switch is in the OFF position, it
exposes a lockout-tagout hole. The switch can be
locked by inserting a lock through the hole. The
switch on the right is pictured in the OFF position.
Emergency Stop Switch
There is one Emergency Stop Switch on the TM-
402. It is located on the left side of the machine
below the Take-up Arm. When an emergency stop
switch is triggered, all motion will be halted and the
machine will require a reset before operation can
continue.
The emergency stop control circuit removes elec-
trical power to all motors, moving parts, heat
sources, pneumatics, and energy storing devices.
This includes the stepper motor drive, stepper
motors, the servo motor drive, servo motors, drive
circuits, the main control board, the heat sealer
and all pneumatics. The only devices that remain
powered are the inspection module cameras, the
enclosure lights, the sensors, and the HMI.

Safety Features D292105.2a.fm ix
Reset Button
The TM-402’s blue Reset button is located on the left side of the machine above the Emergency
Stop Switch. When the machine is powered up, it is automatically placed into an emergency stop
state to prevent the motors from moving until the operator is ready to begin operating the
machine. The error state is cleared by pressing the Reset button on the front of the machine.
Open Doors Stop Operation
All automated motion stops and the machine is unable to enter Run Mode when an enclosure
door is opened. An error message will display at the bottom of the HMI Run screen alerting the
user that the TM-402 door(s) are open.
The enclosure doors may be left open during basic set-up procedures such as positioning the
pick head at place or pick locations. If the enclosure doors are left open during setup the TM-402
automatically reduces the speed of the pick head to a fraction of its normal operating speed to
prevent operator injury due to collision, etc.
Buzzer Alarm
The buzzer alarm will sound and halt the Run Mode process of the machine at any time a System
Alarm occurs. A description of the System Alarm and suggestions for resolving it will appear on
the HMI Main Screen.
Lockout/Tagout
The Main Switch can be turned ON and OFF by turning the
red knob back and forth. When the red knob is placed in the
OFF position, the lockout/tagout hole is exposed. The Main
Switch can then be locked out by placing a lock through the
hole.
The Air Regulator can be turned ON and OFF by turning
the top red cap back and forth. When the red cap is
placed in the OFF position, the lockout/tagout hole will be
exposed. The Air Regulator can then be locked out by
placing a lock through the hole.
Be sure to follow your company guidelines regarding
lockout/tagout procedures.
lockout/tagout hole

Safety Features D292105.2a.fm x
To w e r L i g h t
The tower light feature allows taping machine operators and production
supervisors in determining the operational state of the taping machine at a
glance.
Color Codes
Green
A solid green light indicates the machine is running a job.
Red
A flashing red light indicates that the machine is on but not running.
Green + Amber
The combination of a solid green light and a solid amber light indicate the
machine is at the end of a job and is in the process of creating a leader.
Red + Amber
The combination of a blinking red light and a blinking amber light indicates
the machine is at the end of a job and attempting to create a leader, how-
ever something has interfered with the process, stopping the machine.
A blinking red light and a solid amber light indicates the machine is at the end of a job, the leader
creation sequence is complete and the TM-402 is ready for the next process.