编带机说明书-含图纸ttm402.pdf - 第96页

4-24 TM-403 User’s Guide Configure HMI Settings D292105.7b.fm 15. Save Job Settings a. Browse through the Job Library using the Up/Down Arrow keys to move up or down through the list. T o select a Job Name from the list,…

100%1 / 298
D292105.7b.fm Configure HMI Settings
Chapter 4: Setup 4- 23
13. Verify Job Settings
Test the job settings, using the Pick Part and Place Part buttons to pick and
place parts. If adjustment are required, use the left Arrow key to return to the
desired step and adjust settings. Press the right Arrow Key to move to the next
Job Wizard screen.
Note: Manually placed parts will be counted in the current job.
14. Vision Settings
a. Set Camera State to Enabled or Disabled.
b. If camera is enabled, enter number of Parts Until Inspection (do not include
part at Pick point.). Press the right Arrow Key to move to the final Job Wizard
screen.
Step 6:
Setup HMI
VERIFY
Step 6:
Setup HMI
VISION
4-24 TM-403 User’s Guide
Configure HMI Settings D292105.7b.fm
15. Save Job Settings
a. Browse through the Job Library using the Up/Down Arrow keys to move up or
down through the list. To select a Job Name from the list, press the Enter key.
Note: The Save function will overwrite the information stored for the currently
selected job. Therefore, it is important to select the desired job prior to pressing
the Save button.
b. Press the Save button to save job settings to the selected job name, then
press Finish to close the Job Wizard and return to the main Job Tab.
Step 6:
Setup HMI
SAVE
SETTINGS
D292105.7b.fm Test Seal
Chapter 4: Setup 4- 25
Te s t S e a l
Perform a Seal Test to ensure a good seal. Adjust Sealer settings in the HMI Taper tab as
necessary.
1. Run the tape through the taping module by pressing the Continuous Advance
button in the HMI Taper Tab.
2. As the seal is occurring, watch the alignment of the cover tape with the carrier
tape. The cover tape should run exactly in the groove of the cover tape guide and
the seal should appear as a solid, consistent line. If the seal width is incorrect, stop
the Taper by pressing the Continuous Advance button again.
3. Adjust the seal positions as necessary. The sealer’s inside and outside seals are
independently adjustable. If one of the seals needs to be moved, loosen the
Step 7:
Seal Test
Taper Screen 1