Service Work 3.4.2 Replacing the CPP Head Placement heads Service Manual SIPLACE X Series 129 ► Carefully lift the head out of the locating pins on the head pl ate/from the hook. Installation ► Follow the removal in stru…

100%1 / 384
Service Work
Placement heads 3.4.2 Replacing the CPP Head
128 Service Manual SIPLACE X Series
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 15].
Loosen all four screws fastening the head with a long Torx screwdriver.
CAUTION
Take great care when dismantling the placement head!
The component sensor prisms, underneath the placement head, could be damaged.
Never place the CPP head down on the component sensor.
Fit the protective cap onto the component sensor for
the placement head.
Unplug the compressed air connections (1) from the
placement head. You may want to mark the positions,
to make clear assignment easier later on.
Disconnect the flat ribbon cables (3) from the inter-
mediate distributor (2). You may want to mark the po-
sitions, to make clear assignment easier later on.
Loosen the screws fastening the strain relief (2) on
the component camera cable (1) and carefully unplug
the cable. While unplugging the cable, press the
clamps on both sides of the connector (3). You may
want to mark the positions, to make clear assignment
easier later on.
Service Work
3.4.2 Replacing the CPP Head Placement heads
Service Manual SIPLACE X Series 129
Carefully lift the head out of the locating pins on the head plate/from the hook.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
See also
3.4.2.1 Preparing the Head for the Installation Height [ ➙ 130]
NOTICE
Additional work
If you need to perform further work on this head (e.g. replacing spare parts), fit the head to
the head mount [03056231-xx].
CAUTION
Installation instructions
Observe the correct installation height of the head! Read the service manual for your place-
ment head for more information.
If you replace the head without the component camera, you will need to fit the old camera
onto the new head. Read the service manual for your placement head for more information.
Make sure that the assembly position on the head plate is correct.
Tighten the four fastening screws with a torque of 270 Ncm.
Make sure that the flat ribbon cable is run correctly to the head adapter (see below).
Correct running of flat ribbon cable to head adapter
Make sure that the flat ribbon cable is run correctly to
the head adapter. In particular, the cables must lie in-
side one another at the 90 degrees turn (1) and not
on top of one another, otherwise the connections on
the head adapter could be easily confused.
Service Work
Placement heads 3.4.2 Replacing the CPP Head
130 Service Manual SIPLACE X Series
3.4.2.1
3.4.2.1 Preparing the Head for the Installation Height
Preparing the Head for the Installation Height
Overview
CAUTION
Different heights
The placement head can be installed at two different heights. CPP_L corresponds to a compo-
nent height of six mm. CPP_H corresponds to a component height of 11.5 mm.
If the CPP head is used in a placement area with stationary camera, TwinHead or WPC, it may
only be used in the upper position.
1. Fastening screws on the left side
2. Fastening screws on the right side
This diagram shows the fastening screws in the "head at
top" position.
1. Holding bracket
2. "Head at bottom" position
3. "Head at top" position