Settings 5.2.4 C&P20 Axis Control Service Manual SIPLACE X Series 301 Checking the Z Axis Dynamics Measurement Setup The positioning time for the Z axis is 30 ms +/-3 m s (6 segment h ead) and 24 +/-1 ms DL M2 ( for …

100%1 / 384
Settings
Axis Control 5.2.4 C&P20
300 Service Manual SIPLACE X Series
5.2.4.4
5.2.4.4 Axis Control of Z Axis
Axis Control of Z Axis
Axis control of Z axis
The Z axis DLM2 head is driven via a DC servo motor.
The C&P20 Z axis is driven via a 3~ AC drive. This acti-
vation is via two control signals phase from the VC3 con-
troller Itarget "W" and I-target "U". The intermediate
circuit voltage is approx. 24V.
1. Axis controller board A363 with VC3 controller (VC =
Velocity Commutation) or A 364
2. 1 control signal
3. LEDs on servo amplifier:
4. Servo amplifier
5. 3~ AC(DC) motor.
6. Between the motor and the incremental encoder
there is a fixed mechanical connection.
7. Read unit: transmits the exact position of the axis
(track signals).
8. Elastic mech. connection (belt) and light barrier
down, for fast recognition of the lower position.
The servo board controls the 3~ AC(DC) motor directly.
Settings
5.2.4 C&P20 Axis Control
Service Manual SIPLACE X Series 301
Checking the Z Axis Dynamics
Measurement Setup
The positioning time for the Z axis is 30 ms +/-3 ms (6 segment head) and 24 +/-1 ms DLM2 (for the 12
segment head) for 685 digits. The positioning time Z-C&P20 for 15 mm (equal to the DLM2 path) is
20 ms in both directions. For a path of 0-10000 digits (10 mm), the positioning time should be 16.7 ms.
Position the gantries so that the Z axis is above the calibration component position.
SITEST:
Select C&P heads ==> Select head ==> Axis functions
==> Select Z axis ==> Axis continuous run Select and edit values in digits and accept. Target posi-
tion = 10000 digits (10 mm); Positioning type = absolute.
Signal Example C&P20 Z Axis with the Control Signal at Vnom. Output
NOTICE
Same measurement procedure
The measurement procedure follows the same preparations and procedures as for the star ax-
is.
Z axis dynamic signals for C&P20 -15.4 mm range
1. Motor phase current signal (
Vnom output
)
2. Uncommutated current signal V
reg
3. Deviation of position
4. End signal
15.4 mm (DLM2 path) positioning with the Z axis into free
space
Z axis dynamic signals for C&P20 - calibration tool pocket
1. Motor phase current signal (V
nom
output)
, positioning up in each case
2. Uncommutated current signal V
reg
, positioning downwards
3. Deviation of position
4. End signal
6.8 mm positioning with the Z axis into the calibration tool
pocket
Settings
Axis Control 5.2.4 C&P20
302 Service Manual SIPLACE X Series
5.2.4.5
5.2.4.5 Axis Control of DP Axis
Axis Control of DP Axis
Checking the DP Axis Dynamics
Measurement Setup
The SIPLACE service technician can use special software to start a continuous function run and can, for
example, check the positioning times of the individual DP drives in SITEST (service password).
SITEST:
Select C&P heads ==> Select head ==> Axis functions
==> DP Select the axis ==> Select Axis continuous run and enter the values in 1/100° (start position
0 – target position 18000) position time = absolute
= Start
⇨ The value shown for each individual DP drive should be less than 300 ms at 180°.
Axis control of DP axis for a C&P20 segment
The DP axis of the DLM2 head is driven via a DC servo
motor. The DP axes of the C&P20 segments are posi-
tioned by a DP masterboard and an "on board" direct
control unit. The control system uses CAN Bus at the re-
spective head board. The intermediate circuit voltage is
approx. 24 V. There is no swiveling in or out of a turning
station due to the direct drive in the segment drive motor.
The MC transmits the activation commands via the ma-
chine CAN Bus to the head processor.
This activates via four DP tasks and the head CAN bus
system with activation commands, via the
head adapter
intermediate distributor,
the collector rings of the E/D transformer at the moth-
erboard with the DP motor.
The DP motor control in the segment is handled at the DP
control board with the help of count pulse from the inte-
grated HALL incremental encoder.
NOTICE
No measuring points
There are no measurement points accessible on the C&P20 rotary drives.