Gantry Settings 5.1.7 Track Signals and Zero Pulse
266 Service Manual SIPLACE X Series
5.1.7
5.1.7 Track Signals and Zero Pulse
Track Signals and Zero Pulse
5.1.7.1
5.1.7.1 Checking the Zero Pulse Signal
Checking the Zero Pulse Signal
The zero pulse must be reliably and clearly recognized by the read head. To ensure this, you can check
both the analog and the digital zero pulse. Electronically controlled settings can not be performed on the
incremental length measurement system.
Measuring the Analog Zero Pulse Signal
Measurement procedure for checking the analog zero pulse and the analog track signals
NOTICE
New incremental encoder
Since 2007, machines have been equipped with a new incremental encoder (as in SIPLACE
D4). A larger measuring window allows you to compensate contaminants on the incremental
scale (up to approx. 3.5 mm).
Settings
5.1.7 Track Signals and Zero Pulse Gantry Settings
Service Manual SIPLACE X Series 267
Measurement Procedure
Manually move the gantry over the first zero pulse.
The following picture should appear on the oscilloscope.
Measuring the initial zero pulse position
Connect the measurement tester to the incremental
encoder.
Main power switch ON
Connect the oscilloscope to the measurement tester.
Set the measuring adapter to Calibrate the oscillo-
scope and position the signal at the top center of the
screen.
NOTICE
Zero pulse check
Check the first zero pulse after the limit switch.
Correctly adjusted read unit
1. There should be no interference pulse in the toler-
ance space of - 0.3 V.
2. The analog zero pulse has to exceed the switching
threshold by more then 0.3V
3. Initial position
4. Analog zero pulse
5. Digital zero pulse
Incorrectly adjusted read unit or contaminated zero pulse
1. Analog track signal A and B
2. Analog zero pulse
3. Digital zero pulse
Settings
Gantry Settings 5.1.7 Track Signals and Zero Pulse
268 Service Manual SIPLACE X Series
Measuring the Digital Zero Pulse Signal
Measurement procedure for checking the digital zero pulse signal and the digital track signals.
NOTICE
Checking the zero pulse
You can also use the BNC socket on the axis test box to check the zero pulse signal (inverted
display of zero pulse signal). The digital signals (for error monitoring purposes) can be checked
at connectors X10 and X24 of the gantry and head interface. (Calculate extra time for Y axes,
dismounting the covers).
NOTICE
Procedure for measuring the digital zero pulse
The procedure for measuring the digital zero pulse is identical to that for measuring the analog
zero pulse.