00194440-10_SM_X-Series_Customer_en.pdf - 第24页
Overview of the Modules Serial Number of Module 24 Service Manual SIPLACE X Series 2.1 2 . 1 S e r ia l N u m b e r o f M o d u le Serial Number of Module 2.2 2 . 2 E le c t r ic a l S y s t e m Electrical System Overvie…

Overview of the Modules
Service Manual SIPLACE X Series 23
2
2 Overview of the Modules
Overview of the Modules
SIPLACE X3 - top view
1 Sector 1 8 Computer unit
2 Sector 2 (main distributor) 9 Location for changeover table or MTC2 for
PA 2
3 Sector 3 10 Location for changeover table or MTC2, by
X2 only
4 Sector 4 (subdistributor) 11 Axis unit placement area 1 (PA1)
5 Transport direction 12 Axis unit placement area 2 (PA2)
6 Pneumatic unit and conveyor control 13 Power supply unit
7 Location for changeover table

Overview of the Modules
Serial Number of Module
24 Service Manual SIPLACE X Series
2.1
2.1 Serial Number of Module
Serial Number of Module
2.2
2.2 Electrical System
Electrical System
Overview
See also
3.1 Electrics and Control [ ➙ 49]
The serial number of your placement machine can be
found on the typeplate. This is located on the inside of lo-
cation 1, at the side (1).
Overview (example of X2 shown)
1. Power supply
2. Axis unit
3. Computer unit
4. Main distributor (sector 2)
5. Subdistributor (sector 4)
6. Transport direction

Overview of the Modules
2.2.1 Axis Units Electrical System
Service Manual SIPLACE X Series 25
2.2.1
2.2.1 Axis Units
Axis Units
2.2.1.1
2.2.1.1 Axis Controller
Axis Controller
View and test signals for A364 axis controller of SIPLACE machine
The target position and start signal from the MC are transmitted to the axis controllers, which perform all
necessary calculations and controls.
The axis controller A364 in the SIPLACE machine is slot-coded. This means that no address switch
needs to be set when spare parts are replaced.
The communication and axis control functions are performed by the axis controller.
The corresponding BIOS SW and applications 1 and 2 are responsible for this.
The various drive types (motors) make different entries necessary in the control parameters. This leads
to different firmware versions for the axis types.