Service Work
3.8.5 Replacing the Docked Component Trolley Round Cylinder [03002255-xx] COT Insert HF R2
Service Manual SIPLACE X Series 207
Removal/installation
Place the COT insert down in a suitable position.
CAUTION!
Risk of damage!
Make sure that you do not damage any valves, connec-
tions or cables.
Mark the allocation of the compressed air connec-
tions and disconnect them from the round cylinder.
Remove the cylinder cover (1).
Undo the circlip (2) on the fork head (3) with a suitable
pair of circlip pliers
Carefully knock the shafts out of their guides. Make
sure that you do not lose the two shim rings.
Loosen the screws fastening the cam disk unit (4)
and carefully lever it out of the locating pins.
Undo the circlips (1) on the axes and gently knock the
shafts (2) out of the articulated joint.
Remove the round cylinder (3).
First install the new round cylinder and then the other
parts in reverse order.
Plug in the compressed air connections in the correct
allocation.
1. Speed adjustment valve – docked
2. Speed adjustment valve - undocked
Fit the complete COT insert into the machine again.
Set the round cylinder speed so that the left and right
cam disk unit run parallel to one another.
(time needed to move in/out approx. 2 s)
Adjust the setting screw on each docking (1) and un-
docking (2) valve accordingly.
This ensures that the component trolley is not distort-
ed when moved in.
Service Work
COT Insert HF R2 3.8.6 Replacing the Empty-Tape Duct Assembly [03003725-xx]
208 Service Manual SIPLACE X Series
3.8.6
3.8.6 Replacing the Empty-Tape Duct Assembly [03003725-xx]
Replacing the Empty-Tape Duct Assembly [03003725-xx]
Removal/installation
1. COT insert assembly
2. Cutter, complete
3. Empty-tape duct assembly
Remove the complete COT insert from the machine.
Loosen the screws fastening the centering bar (4).
Remove the centering bar (4).
Mark the position of the sensors (6) (reed contacts)
and remove these from the reject container.
Loosen the screws (5) holding the empty-tape duct
assembly (3).
Carefully lift the empty-tape duct (3) out of the COT
insert (1).
Fit the sensors (1) (reed contacts) for the reject con-
tainer (2).
NOTICE!
These sensors are installed in different positions, accord-
ing to the configuration of the machine.
Fit the empty-tape duct and the centering bar.
Service Work
3.8.7 Replacing the Baffles [03002191-xx] COT Insert HF R2
Service Manual SIPLACE X Series 209
3.8.7
3.8.7 Replacing the Baffles [03002191-xx]
Replacing the Baffles [03002191-xx]
Overview
Removal/installation
1. Empty-tape duct assembly
2. Baffles
1. Baffle, outside
2. Baffle, inside
3. Baffle insert
4. Side panels
NOTICE!
All screws are accessible in the installed state. The baf-
fles can therefore be replaced inside the machine.
Replace the individual baffles as described below:
Loosen the four screws (5) fastening the "baffle, out-
side" on both side panels.
Loosen the four screws (6) fastening the "baffle, in-
side" on both side panels.
Loosen the two screws (7) fastening the baffle insert.